Philio Technology Corporation PAN03 Скачать руководство пользователя страница 3

 

 
 

Adding to Z-Wave

TM

 Network

 

 
In the front casing, there is an On/Off button with LED indicator which is used to toggle 
switch  on  and  off  or  carry  out  inclusion,  exclusion,  reset  or  association.  When  first 
power is applied, its LED flashes on and off alternately and repeatedly at 0.5 second 
intervals. It implies that it has not been assigned a node ID and start auto inclusion. 

 

 
Auto Inclusion

 

 
The function of auto inclusion will be executed as long as the switch does not have

 

Node ID and just plug the switch into a wall outlet.

 

 
Note:
 Auto inclusion timeout is 2 minute during which the node information of explorer 
frame will be emitted once several seconds. Unlike “inclusion” function as shown in 
the table below, the execution of auto inclusion is free from pressing the On/Off button 
on the Switch.

 

 
The table below lists an operation summary of basic Z-Wave functions. Please refer to 
the instructions for your Z-Wave

TM

 Certificated Primary Controller to access the Setup 

function, and to Add/Remove/Reset/Associate devices

 

 

Function

 

Description

 

Annotation

 

No node ID

 

The Z-Wave Controller does not allocate 
a node ID to the Switch.

 

2-second on, 2-second off

 

Add

 

(Inclusion)

 

1.

 

Put your Z-Wave controller into

 

inclusion mode by following the

 

instructions provided by the

 

controller manufacturer.

 

 

To support handling of 

the device when already 
installed the external switch 
can be used for inclusion or 
exclusion for 3 minutes 
after power up.

 

2.    Pressing On/Off button three times 

within 2 seconds will enter inclusion 
mode.

 

Remove

 

(Exclusion)

 

1.    Put your Z-Wave controller into

 

exclusion mode by following the

 

instructions provided by the

 

controller manufacturer.

 

 

To support handling of 

the device when already 
installed the external switch 
can be used for inclusion or 
exclusion for 3 minutes 
after power up.

 

2.

 

Pressing On/Off button three times 
within 2 seconds will enter exclusion 
mode.

 

Node ID has been excluded.

 

0.5s On, 0.5s Off (Enter 
auto inclusion)

 

Reset

 

1. 

Pressing On/Off button three times 
within 2 seconds will enter inclusion 
mode.

 

Use this procedure only in

 

the event that the primary

 

controller is lost or

 

otherwise inoperable.

 

2. 

Within 1 second, press On/Off 
button again for 5 seconds.

 

3. 

IDs are excluded.

 

0.5s On, 0.5s Off (Enter 
auto inclusion)

 

Association

 

1.  The PAN03 is an always listening

 

Z-Wave device, so associations may

 

be added or removed by a controller

 

at any time.

 

Or    If your controller requires to have

 

the PAN03 send a 'node information

 

frame' or NIF for associations, then

 

pressing the On/Off button three

 

times within 2 seconds will cause

 

the PAN03 to send its NIF.

 

 

2.    There are only one group for the 

switch

 

 

Adding a node ID allocated by Z-Wave Controller means inclusion.    Removing a node

 

ID allocated by Z-Wave Controller means exclusion.

 

Failed or success in including/excluding the node ID can be viewed from the Z-Wave 

Controller.   

Sometimes people are not easy to execute exclusion or inclusion especially when

 

PAN03 already installed in a wall box. To solve this issue, PAN03 support a special

 

feature that can use S1 or S2 to execute “exclusion, inclusion, Reset or Association”

 

at the first 3 minutes when first time connect to main power 

 

 

 

LED Indication

 

To distinguish what mode the switch is in, view from the LED for identification.

 

 

State Type

 

LED Indication

 

Normal

 

Whenever we switch On and off of the PAN03 by S1

S2 or On/Off 

button or RF command, the LED will lights up 1 second and then 
off.

 

No node ID

 

Under normal operation, when the Switch has not been allocated a 
node ID, the LED flashes on and off alternately at 2-second 

Содержание PAN03

Страница 1: ...ill reset its overload condition to normal status Safety Precautions and Installation Avoid installing the unit in storming or raining weather Be sure to isolate or switch off power source before installing or maintenance Do ensure that the power supply circuit protected by a 16A circuit breaker or suitable equivalent fuse IMPORTANT Installation must be performed by skilled technicians who are inf...

Страница 2: ...y out association 2 Wait for a while to re try LED keep flashing but cannot control Overload occurs Remove the load attached or check max load cannot exceed 12 0A Resistive load Installation Fig 1 PAN03 Assembling For Instruction to http www philio tech com DANGER Danger of electrocution All works on the device may be performed only by a qualified and licensed electrician Observe national regulati...

Страница 3: ...ng of the device when already installed the external switch can be used for inclusion or exclusion for 3 minutes after power up 2 Pressing On Off button three times within 2 seconds will enter exclusion mode Node ID has been excluded 0 5s On 0 5s Off Enter auto inclusion Reset 1 Pressing On Off button three times within 2 seconds will enter inclusion mode Use this procedure only in the event that ...

Страница 4: ...lowing commands from a Z Wave Controller the Switch will report its On Off state to the node asked Basic Get Command Command Class Basic Basic Get Basic Report Command Report OFF Command Class Basic Basic Report Value 0 0x00 Report ON Command Class Basic Basic Report Value 255 0xFF Binary Switch Get Command Command Class Switch Binary Switch Binary Get Binary Switch Report Command Report OFF Comma...

Страница 5: ...Controller after receive the Meter Get Command from Z Wave Controller 2 2 1 Instant Power Consumption Watt of Switch When receiving Meter Get Command it will report Meter Report Command to the node Meter Get Command Command Class Meter Meter Get Scale 0x02 W Meter Report Command Command Class Meter Meter Report Rate Type 0x01 Meter Type 0x01 Precision 1 Scale 0x02 Size 4 Meter Value W Example Mete...

Страница 6: ... receiving Meter Get Command it will report Meter Report Command to the node Meter Get Command Command Class Meter Meter Get Scale 0x06 PF Meter Report Command Command Class Meter Meter Report Rate Type 0x01 Meter Type 0x01 Precision 2 Scale 0x06 Size 1 Bytes Meter Value PF Example Scale 0x06 PF Precision 2 Size 1 1 Byte of PF Meter Value 1 0x63 PF Load power factor PF Meter Value 1 0 99 3 Z Wave ...

Страница 7: ... from lost PAN03 will restore the switch state which could be SWITCH OFF LAST SWITCH STATE SWITCH ON The default setting is LAST SWITCH STATE 3 6 Manual On Off Mode The On Off function of S1 S2 and learn switch can be disabled or enabled by this parameter default value is Enable But the learning operation won t be affected When manual On Off function is disabled the RF command can only switch On b...

Страница 8: ...ion Command Class version 2 it can protect the switch against unintentionally control by e g a child And it can also protect the switch from being turned off by setting it in No RF Control state After being set to Protection by sequence state any intentional pressing of On Off button should be hold longer than 1 second or the switch state will not change However the operation of learn function doe...

Страница 9: ...f and on the user is encouraged to try to correct the interference by one of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This device complies with P...