Philio Technology Corporation PAN03 Скачать руководство пользователя страница 2

 

 

Troubleshooting

 

                                 

 

Symptom

 

Cause of Failure

 

Recommendation

 

The Switch not working and 
LED off

 

1.

 

The Switch is not 
plugged into the 
electrical outlet 
properly

 

2.

 

The Switch break down

 

1.

 

Check power connections

 

2. Don’t open up the Switch and send 

it for repair.

 

The Switch LED 
illuminating, but cannot 
control the ON/OFF

 

Switch of the load attached

 

1.Check if the load 

plugged into the Switch 
has its own ON/OFF 
switch

 

2. The switch is protected

 

1. Set the ON/OFF switch of the load 

attached to ON

 

2. Unprotected the switch or follow 

the instruction of protection.

 

The Switch LED 
illuminating, but the 
Detector cannot control

 

the Switch

 

1. Not carry out 

association

 

2. Same frequency 

interference

 

1. Carry out association

 

2. Wait for a while to re-try

 

LED keep flashing, but 
cannot control

 

Overload occurs

 

Remove the load attached or check 
max. load cannot exceed 
12.0A(Resistive load)

 

 

Installation

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Fig 1. PAN03 Assembling

 

For Instruction to http:// www.philio-tech.com

 

 
 
 
 
 
 
 
 
 

 

DANGER

 

     

Danger of electrocution!

 

All works on the device may be performed only by a qualified and licensed electrician. 

Observe national regulations. 

 

Any works introducing changes into the configuration must be always performed with 

disconnected voltage. 

 

 

Choosing a Suitable Location

 

1. Do not locate the Module facing direct sunlight, humid or dusty place.

 

2. The suitable ambient temperature for the Module is 0°C~40°C.

 

3. Do not locate the Module where exists combustible substances or any source of 

heat, e.g. fires, radiators, boiler etc.

 

4.  After  putting  it  into  use,  the  body  of  Module  will  become  a  little  bit  hot  of  which 

phenomenon is normal.

 

 

Содержание PAN03

Страница 1: ...ill reset its overload condition to normal status Safety Precautions and Installation Avoid installing the unit in storming or raining weather Be sure to isolate or switch off power source before installing or maintenance Do ensure that the power supply circuit protected by a 16A circuit breaker or suitable equivalent fuse IMPORTANT Installation must be performed by skilled technicians who are inf...

Страница 2: ...y out association 2 Wait for a while to re try LED keep flashing but cannot control Overload occurs Remove the load attached or check max load cannot exceed 12 0A Resistive load Installation Fig 1 PAN03 Assembling For Instruction to http www philio tech com DANGER Danger of electrocution All works on the device may be performed only by a qualified and licensed electrician Observe national regulati...

Страница 3: ...ng of the device when already installed the external switch can be used for inclusion or exclusion for 3 minutes after power up 2 Pressing On Off button three times within 2 seconds will enter exclusion mode Node ID has been excluded 0 5s On 0 5s Off Enter auto inclusion Reset 1 Pressing On Off button three times within 2 seconds will enter inclusion mode Use this procedure only in the event that ...

Страница 4: ...lowing commands from a Z Wave Controller the Switch will report its On Off state to the node asked Basic Get Command Command Class Basic Basic Get Basic Report Command Report OFF Command Class Basic Basic Report Value 0 0x00 Report ON Command Class Basic Basic Report Value 255 0xFF Binary Switch Get Command Command Class Switch Binary Switch Binary Get Binary Switch Report Command Report OFF Comma...

Страница 5: ...Controller after receive the Meter Get Command from Z Wave Controller 2 2 1 Instant Power Consumption Watt of Switch When receiving Meter Get Command it will report Meter Report Command to the node Meter Get Command Command Class Meter Meter Get Scale 0x02 W Meter Report Command Command Class Meter Meter Report Rate Type 0x01 Meter Type 0x01 Precision 1 Scale 0x02 Size 4 Meter Value W Example Mete...

Страница 6: ... receiving Meter Get Command it will report Meter Report Command to the node Meter Get Command Command Class Meter Meter Get Scale 0x06 PF Meter Report Command Command Class Meter Meter Report Rate Type 0x01 Meter Type 0x01 Precision 2 Scale 0x06 Size 1 Bytes Meter Value PF Example Scale 0x06 PF Precision 2 Size 1 1 Byte of PF Meter Value 1 0x63 PF Load power factor PF Meter Value 1 0 99 3 Z Wave ...

Страница 7: ... from lost PAN03 will restore the switch state which could be SWITCH OFF LAST SWITCH STATE SWITCH ON The default setting is LAST SWITCH STATE 3 6 Manual On Off Mode The On Off function of S1 S2 and learn switch can be disabled or enabled by this parameter default value is Enable But the learning operation won t be affected When manual On Off function is disabled the RF command can only switch On b...

Страница 8: ...ion Command Class version 2 it can protect the switch against unintentionally control by e g a child And it can also protect the switch from being turned off by setting it in No RF Control state After being set to Protection by sequence state any intentional pressing of On Off button should be hold longer than 1 second or the switch state will not change However the operation of learn function doe...

Страница 9: ...f and on the user is encouraged to try to correct the interference by one of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This device complies with P...

Отзывы: