Philio Technology Corporation PAN03 Скачать руководство пользователя страница 5

 

node of Grouping 1. 

 

     

 

Binary Switch Report

 

 

ON:[Command Class Switch Binary, Switch Binary Report, Value 

=255(0xFF)]

 

OFF:[Command Class Switch Binary, Switch Binary Report, Value 

=0(0x00)]

 

 

2-1-2 Instant Power Consumption vary over 5% report

 

 
When the power consumption of load vary over 5%, it will send Meter report to the 
nodes of Grouping 1.

 

 

Meter Report Command: 

 

[Command Class Meter

Meter Report

Rate Type = 0x01

Meter Type =

 

0x01

Precision = 1

Scale = 0x02

Size = 4

Meter Value(W) ]

 

 
  2-1-3 Overload alarm report

 

When  PAN03  detects  the  current  is  more  than  12A,  it  will  send  Alarm  Report  to 
Group 1 node. 

 

The content of Alarm Report 

 

Alarm report command:

    [Command_Class_Alarm, Alarm_Report, Alarm Type = 0x08, 

[Command_Class_Alarm, Alarm_Report, Alarm Type = 0x08, 

[Command_Class_Alarm, Alarm_Report, Alarm Type = 0x08, 

[Command_Class_Alarm, Alarm_Report, Alarm Type = 0x08, 

Alarm Level =

Alarm Level =

Alarm Level =

Alarm Level =    0xFF]

0xFF]

0xFF]

0xFF] 

 
2-2 Response to Meter Get Command

 

      The  Switch  will  report  its  (1)  instant  Power  Consumption  (Watt)    or  (2) 

accumulated power consumption(KWH) or (3)

 

AC load Voltage (V) or (4)

 

AC load 

current  (  I  )  (5)

 

load  power  factor  (PF)    to  Z-Wave  Controller  after  receive  the 

Meter Get Command from Z-Wave Controller.

 

 
2-2-1 Instant Power Consumption (Watt) of Switch

 

        When receiving Meter Get Command, it will report Meter Report Command to the 

node.

 

 

Meter Get Command: [Command Class Meter, Meter Get, Scale =0x02(W)]

 

Meter Report Command: 

 

[Command Class Meter

Meter Report

Rate Type = 0x01

Meter Type =

 

0x01

Precision = 1

Scale = 0x02

Size = 4

Meter Value(W) ]

 

 

Example:

 

Meter Value 1 = 0x00 (W)

 

Meter Value 2 = 0x00 (W)

 

Meter Value 3 = 0x03 (W)

 

Meter Value 4 = 0xEA (W)

 

Meter(W) = Meter Value 3 *256 + Meter Value 4 = 100.2W

 

 
2-2-2 Accumulated Power Consumption (KW/h)

 

When receiving Meter Get Command, it will report Meter Report Command to

 

the node.

 

 

Meter Get Command: [Command Class Meter, Meter Get, Scale = 0x00 KW/h)]

 

Meter Report Command:

 

  [Command Class Meter

Meter Report

Rate Type = 0x01

, 

Meter Type =

 

0x01

, 

Precision = 2

Scale = 0x00

Size = 4

Meter Value (KWh)]

 

 
          Example:

 

          Scale = 0x00 (KWh)

 

          Precision = 2

 

          Size = 4 Bytes (KW/h)

 

          Meter Value 1 = 0x00(KWh)

 

          Meter Value 2 = 0x01(KWh)

 

          Meter Value 3 = 0x38(KWh)

 

          Meter Value 4 = 0xA3(KWh)

 

 
          Accumulated  power  consumption  (KW/h)  =  (Meter  Value  2*65536)  +  (Meter 

Value 3*256) + (Meter Value 4) = 800.35 (KW/h)

 

 
2-2-3 Clearing accumulated power consumption

 

Whenever re-start counting the accumulated power consumption is needed, you

 

can use Meter Reset Command to clear it.

 

 

Meter Reset Command: [Command Class Meter, Meter Reset]

 

 

 

Содержание PAN03

Страница 1: ...ill reset its overload condition to normal status Safety Precautions and Installation Avoid installing the unit in storming or raining weather Be sure to isolate or switch off power source before installing or maintenance Do ensure that the power supply circuit protected by a 16A circuit breaker or suitable equivalent fuse IMPORTANT Installation must be performed by skilled technicians who are inf...

Страница 2: ...y out association 2 Wait for a while to re try LED keep flashing but cannot control Overload occurs Remove the load attached or check max load cannot exceed 12 0A Resistive load Installation Fig 1 PAN03 Assembling For Instruction to http www philio tech com DANGER Danger of electrocution All works on the device may be performed only by a qualified and licensed electrician Observe national regulati...

Страница 3: ...ng of the device when already installed the external switch can be used for inclusion or exclusion for 3 minutes after power up 2 Pressing On Off button three times within 2 seconds will enter exclusion mode Node ID has been excluded 0 5s On 0 5s Off Enter auto inclusion Reset 1 Pressing On Off button three times within 2 seconds will enter inclusion mode Use this procedure only in the event that ...

Страница 4: ...lowing commands from a Z Wave Controller the Switch will report its On Off state to the node asked Basic Get Command Command Class Basic Basic Get Basic Report Command Report OFF Command Class Basic Basic Report Value 0 0x00 Report ON Command Class Basic Basic Report Value 255 0xFF Binary Switch Get Command Command Class Switch Binary Switch Binary Get Binary Switch Report Command Report OFF Comma...

Страница 5: ...Controller after receive the Meter Get Command from Z Wave Controller 2 2 1 Instant Power Consumption Watt of Switch When receiving Meter Get Command it will report Meter Report Command to the node Meter Get Command Command Class Meter Meter Get Scale 0x02 W Meter Report Command Command Class Meter Meter Report Rate Type 0x01 Meter Type 0x01 Precision 1 Scale 0x02 Size 4 Meter Value W Example Mete...

Страница 6: ... receiving Meter Get Command it will report Meter Report Command to the node Meter Get Command Command Class Meter Meter Get Scale 0x06 PF Meter Report Command Command Class Meter Meter Report Rate Type 0x01 Meter Type 0x01 Precision 2 Scale 0x06 Size 1 Bytes Meter Value PF Example Scale 0x06 PF Precision 2 Size 1 1 Byte of PF Meter Value 1 0x63 PF Load power factor PF Meter Value 1 0 99 3 Z Wave ...

Страница 7: ... from lost PAN03 will restore the switch state which could be SWITCH OFF LAST SWITCH STATE SWITCH ON The default setting is LAST SWITCH STATE 3 6 Manual On Off Mode The On Off function of S1 S2 and learn switch can be disabled or enabled by this parameter default value is Enable But the learning operation won t be affected When manual On Off function is disabled the RF command can only switch On b...

Страница 8: ...ion Command Class version 2 it can protect the switch against unintentionally control by e g a child And it can also protect the switch from being turned off by setting it in No RF Control state After being set to Protection by sequence state any intentional pressing of On Off button should be hold longer than 1 second or the switch state will not change However the operation of learn function doe...

Страница 9: ...f and on the user is encouraged to try to correct the interference by one of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This device complies with P...

Отзывы: