11
AutoFlex layout
1
Mounting board:
make sure all module boards, incoming power, and the ribbon cable from the communication
controller are properly connected.
2
Incoming power terminal:
connect 120/230 VAC, 50/60 Hz power. See page 25.
3
Ground terminals:
connect any equipment grounds to these terminals. See page 25.
4
12 VDC output terminal:
connect any equipment that requires 12 VDC power, such as iWire radios. You cannot
connect VFDs here.
5
ON/OFF switch:
switch the AutoFlex ON or OFF using this switch.
6
Cable trough:
route AC power equipment cables through the trough. Route data and signal cables along the inner
walls of the enclosure.
7
Communication controller:
make sure the ribbon cable is connected from the communication controller to the
mounting board.
8
Slave cable connection:
connect an optional AutoFlex Slave unit here.
9
Alarm relay terminal:
If you have an external alarm system, connect it here. See page 23.
10 Display controller:
make sure the power supply (top board) is properly connected to the bottom board, and all
cables are properly connected.
11 USB drives:
(appearance may vary) make sure the USB drives are properly connected to the USB ports.
12 USB cable:
make sure the cable is properly connected from the display controller to the display board.
13 HDMI cable:
make sure the cable is properly connected from the controller board to the display board.
13
2
11
6
1
3
10
8
5
4
9
7
12