F.
Power on and test the system
1.
Read the
Important power supply information
below.
2.
Switch on the power to the control and wait for the startup process to complete.
3.
Make sure the system is functioning normally.
If there is no power or no display make sure the ribbon cables are properly connected.
If there is no display, make sure the HDMI and power cables are properly connected.
Screen does not respond to touches, make sure the USB cable is properly connected.
4.
Close the cover and tighten the three screws.
Important information about the power supply
Immediately after powering up the control, remove the plastic tab
(A)
from between
the battery and contact of the battery holder.
If the control will be powered off for more than two days
1.
Shut down the control normally.
2.
Wait for L6
(B)
to go OFF.
3.
Reinsert the tab between the battery and contact. L1 and L2
(C)
will be OFF when the tab is
correctly inserted.
A
C
B
Phason
2 Terracon Place
Phone: 204-233-1400
Winnipeg, Manitoba, Canada
E-mail: [email protected]
R2J 4G7