13
12
Table 2 – Camera Control Cable Description
Connector Pin
Color
Name
Description
Direction Level
Notes
1 Orange Reserved
Reserved
Reserved Reserved
Reserved
2 Green
System
Ready
iXU-RS/iXU-R/iXU
system ready for
next capture
Out
VOH, min = 4.0 V (Io = -10uA)
VOL, max = 0.8 V (Io = 4mA)
Isolated
5 Volt Level
Pull up resistor
100K Ohms to +5 V
3 Red
Black
Reference
Control
Indicates a black
reference sequence
is required
In
VIH, min = 2.4 V
VIL, max = 0.8 V
tiF, tiR < 1uSec
Isolated, active low
See "Understanding
Black Reference"
on page 14
4 Purple
Trigger In
Trigger the iXU-RS/
iXU-R/iXU for new
capture cycle
In
VIH, min = 2.4 V
VIL, max = 0.8 V
tiF, tiR < 1uSec
Isolated, active low
(For manual
triggering, activate
by short to common
signal, otherwise
leave floating.)
5 Blue
RS232 RX
External system
can send specific
information to iXU-
RS/iXU-R/iXU system
In
RS232 input level +/- 15 V
(VIT+ max=2.4 V
VIT-min=0.8 V)
RS232 Voltage
Level Isolated
For baud rate
and additional
information,
see the Phase One
GPS User Guide
6 Yellow
RS232 TX
iXU-RS/iXU-R/iXU
system can send
specific information
to external system
Out
VOH at RL=3 kΩ to GND
+ 5.4 V
VOL at RL=3 kΩ to GND
–5.4 V
7 White
Mid-exposure
pulse
Midpoint of the
exposure time
Out
VOH, min = 4.0 V (Io= - 4mA)
VOL, max = 0.8 V (Io= 4mA)
Isolated
5 Volt Level
8 Gray
Reserved
Reserved
In
Short to pin 9*
9 Black
Common
Common
*For iXU-RS/iXU-R/iXU cameras, this connection is
mandatory.
The connection is not necessary for iXA-R/iXA cameras.
VIL — maximum voltage level that is interpreted as a ‘0’ by a input.
VIH — minimum voltage level that is interpreted as a ‘1’ by a input.
VOL — guaranteed maximum voltage level that appears on
output set to ‘0’.
VOH — guaranteed minimum voltage level that appears on
output set to ‘1’.
VIT+ — input threshold voltage when the input voltage is rising.
VIT– — input threshold voltage when the input voltage is falling
Wiring a Control Cable