• The wireless remote can be used at a distance of up to 25 metres. You can choose 2 ways to control,
depending on the settings you make in the menu.
• The wireless remote has 4 buttons, A,B,C,D. Depending the menu settings the remote can control 4 colours
or 4 zones.
First Time Operation With DMX:
• Before you start using this unit, please check there is no transportation damage, should there be any, please
do not use the device and contact your dealer immediately.
• The PFX1500V is designed to be used with water based smoke, fog or vapour liquid.
• Put the smoke machine on a flat stable surface or truss mount following the instructions in this manual
carefully. Make sure no one can put any body part close to the heater output.
• Unscrew the Lid on the fluid bottle, fill up with a suitable fog liquid, do not to overfill. Screw the plastic cap
back on and ensure the tank never runs dry during operation.
• Connect a DMX controller to the DMX input socket. Terminate the output socket or connect to other DMX
fixtures.
• Plug the mains plug into a suitable mains supply. Allow the unit to warm up for around 4 minutes
This unit uses 4 channels of DMX.
• Set a suitable DMX address via the digital display.
DMX Channel Layout:
There is some useful DMX info at the end of this manual.
Overhead Rigging:
The installation must be carried out by a qualified engineer only. Improper installation can result in injuries or
damage to property. Overhead rigging requires experience, working loads should be adhered to and certified
materials should be used. The installed device should be regularly inspected for safety.
• Make sure the working area is clear from people and obstructions during rigging, de rigging and servicing.
• Locate the smoke machine in a well ventilated area away from flammable materials and liquids. The smoke
machine needs to be 50cm away from surrounding walls and fixtures.
• The smoke machine should be installed out of reach of people and not where people are seated, walking or standing.
• When mounting make sure the installation point can take the weight.
• Make sure a safety chain or wire is always used and can take the weight of the smoke machine. The safety
bond should not be used as a primary support.
• The machine should be well fixed and free from swinging.
• Do not cover any ventilation holes.
• Disconnect the power when the machine is not in use.
• The operator must make sure the smoke machine has been installed correctly to all the necessary
guidelines before each use. The installation should be inspected every 6 months.
Channel:
Value:
Function:
1
000-005
NO fog output
006-255
FOG output ON
2
000-005
No Colour
006-085
RED
086-170
GREEN
171-255
BLUE
3
000-005
No Colour
006-085
RED + BLUE
086-170
GREEN + RED
171-255
BLUE + GREEN
4
000-005
No Colour
006-085
RANDOM Colour