Page 29 of 49
3. Ductile Iron
4. Copper
5. PVC
6. Aluminum
7. Asbestos
8. Fiber Glass-Epoxy
9. Other
Refer to item 9 "Other"; it is possible to enter other
materials, which are not included in previous eight
items. Once item 9 is selected, the relevant pipe sound
velocity must be entered in Window M15. If sound
velocity is not known, there are other ways to
determine it on site.
Pipe Sound Velocity
Enter pipe sound velocity. This function is only used
when item 9 "Other" is selected in Window M14. At
the same time, this window cannot be visited. It will
be calculated automatically according to the existing
parameters.
Select the Liner Material
The following options are available:
0.
None ,No Liner
1.
Tar Epoxy
2.
Rubber
3.
Mortar
4.
Polypropylene
5.
Polystyrol
6.
Polystyrene
7.
Polyester
8.
Polyethylene
9.
Ebonite
10.
Teflon
11.
Othe
Item 11 "Other" is available to enter other materials
that are not included in previous ten items. Once the
"Other" is selected, the relevant liner sound velocity
must be entered in Window M17.