![Pfister Contempra 49 Series Скачать руководство пользователя страница 5](http://html.mh-extra.com/html/pfister/contempra-49-series/contempra-49-series_manual_1535439005.webp)
ENGLISH
ENGLISH
13
14
16
FAUCET FUNCTIONS
MAINTENANCE & CARE
15
CAUTION: Maintenance
DISASSEMBLY
1. Replacement parts may be available at the store where you purchased
your faucet.
2. When replacement parts are not available, please write or call Price Pfister
Consumer Service.
3.
Always turn off water and relieve pressure before working on your
faucet.
NOTE: Trim Care
Cleaning Instructions:
For all Handles and decorative finishes, use only a soft damp cloth
to clean and shine. Use of polish, detergents, abrasive cleaners,
organic solvents or acid may cause damage.
Use of other than
a soft damp cloth will nullify our warranty!
Special Trim:
Trim products which contain Porcelain or other similar substance
are not acceptable for public areas or Commercial use. Installation
of Said Trim is at Users Risk!
1–800–PFAUCET (1–800–732–8238)
For Toll-Free Pfaucet information call
1–800–PFAUCET (1–800–732–8238)
or visit www.pricepfister.com
• Installation Support
• Care and Warranty Information
13 UNIT START UP
Turn on hot and cold water supplies, and check for leaks above and below the sink.
14 FAUCET FUNCTION
COLD valve: close-counterclockwise, open-clockwise; HOT valve: close-clockwise,
open-counterclockwise. The Spout (
14A
) can be rotated from side to side.
Note:
Flush faucet before turning on valve (
see step 15
).
15 FLUSHING & AERATOR CLEANING
After installation is complete, remove Aerator Housing (
15A
). Turn Valves (
15B
) on
and allow both hot and cold water to run for at least one minute each. While water is
running, check for leaks. To clean the aerator, disassemble Aerator Housing (
15A
) by
separating the Aerator Shell (
15C
), Basket (
15D
), and Washer (
15E
). Once parts have
been cleaned, reassemble by reversing steps.
16 VALVE CARTRIDGE REMOVAL
Turn off water supplies and relieve pressure before working on your faucet
(
see
step 2
).
Remove Handles (
16A
) and
remove Valve Adapter (
16B
) (
see step 7
).
Unscrew
Retainer Nut (1
6C
) by turning it counter-clockwise and lift out Cartridge Assembly (
16D
)
and inspect. Replace parts as necessary.
5
16A
16C
16D
16B
HOT
COLD
OPEN
OPEN
14A
15A
15B
15E
15D
15C