background image

Accessories

37

12

Accessories

12.1 HiPace 400, 48 V DC

Designation

DN 100 ISO-K

DN 100 CF-F

DN 100 ISO-F

Mounting kit for HiPace 400, DN 100 ISO-K, including coated center-
ing ring

PM 016 380 -T

Mounting kit for HiPace 400, DN 100 ISO-K, including coated center-
ing ring, protection screen, bracket screws

PM 016 382 -T

Mounting kit for HiPace 400, DN 100 ISO-K, including coated center-
ing ring, splinter shield, bracket screws

PM 016 381 -T

Mounting kit for DN 100 ISO-K to ISO-F, with collar flange, coated cen-
tering ring, hexagon bolts

PM 016 940 -T

Mounting kit for DN 100 ISO-K to ISO-F, with collar flange, coated cen-
tering ring with splinter shield, hexagon bolts

PM 016 941 -T

Mounting kit for DN 100 ISO-K to ISO-F, with collar flange, coated cen-
tering ring with protection screen, hexagon bolts

PM 016 942 -T

Mounting kit for DN 100 ISO-K to ISO-F, with collar flange, coated cen-
tering ring, stud screws

PM 016 945 -T

Mounting kit for DN 100 ISo-K to ISO-F, with collar flange, coated cen-
tering ring with splinter shield, stud screws

PM 016 946 -T

Mounting kit for DN 100 ISO-K to ISO-F, with collar flange, coated cen-
tering ring with protection screen, stud screws

PM 016 947 -T

Set of hexagon screws for through hole, DN 100 CF-F

PM 016 690 -T

Set of stud screws for tapped hole, DN 100 CF-F

PM 016 866 -T

Set of stud screws for through hole, DN 100 CF-F

PM 016 734 -T

Mounting kit for DN 100 ISO-F, including coated centering ring, hexa-
gon screws

PM 016 450 -T

Mounting kit for DN 100 ISO-F, including coated centering ring, protec-
tive screen, hexagon screws

PM 016 452 -T

Mounting kit for DN 100 ISO-F, including coated centering ring, splin-
ter shield, hexagon screws

PM 016 451 -T

Mounting kit for DN 100 ISO-F, including coated centering ring, stud 
screws

PM 016 455 -T

Mounting kit for DN 100 ISO-F, including coated centering ring, protec-
tion screen, stud screws

PM 016 457 -T

Mounting kit for DN 100 ISO-F, including coated centering ring, splin-
ter shield, stud screws

PM 016 456 -T

Centering ring with multifunction coating, DN 100 ISO-K/-F

PM 016 210 -U

PM 016 210 -U

Centering ring with multifunction coating and integrated protection 
screen, DN 100 ISO-K/-F

PM 016 212 -U

PM 016 212 -U

Centering ring with multifunction coating and integrated splinter 
shield, DN 100 ISO-K/-F

PM 016 211 -U

PM 016 211 -U

Vibration damper for HiPace 300/400, DN 100 ISO-K/F

PM 006 459 -X

PM 006 459 -X

Protection screen for DN 100 CF-F

PM 016 336

Splinter shield for turbopumps, DN 100 CF-F

PM 016 315

Vibration damper for HiPace 300/400, DN 100 CF-F

PM 006 488 -X

TPS 400, power supply 48 V DC, for wall/standard rail fitting

PM 061 343 -T

PM 061 343 -T

PM 061 343 -T

TPS 401, power supply 48 V DC, 19" partial plug-in 3HU

PM 061 347 -T

PM 061 347 -T

PM 061 347 -T

DCU 400, Display control unit incl. power supply

PM C01 823

PM C01 823

PM C01 823

Mains cable 230 V AC, CEE 7/7 to C13, 3 m

P 4564 309 ZA

P 4564 309 ZA

P 4564 309 ZA

Mains cable 115 V AC, NEMA 5-15 to C13, 3 m

P 4564 309 ZE

P 4564 309 ZE

P 4564 309 ZE

Mains cable 208 V AC, NEMA 6-15 to C13, 3 m

P 4564 309 ZF

P 4564 309 ZF

P 4564 309 ZF

DCU 002, Display Control Unit

PM 061 348 -T

PM 061 348 -T

PM 061 348 -T

HPU 001, Handheld Programming Unit

PM 051 510 -T

PM 051 510 -T

PM 051 510 -T

Accessories package for HPU 001/PC

PM 061 005 -T

PM 061 005 -T

PM 061 005 -T

Connection cable for HiPace with TC 400/TM 700 to power supply 
TPS/DCU 310/311/400/401

PM 061 352 -T

PM 061 352 -T

PM 061 352 -T

Backing pump relay box, single phase 20 A, for TC 400 and TCP 350, 
M12 plug

PM 061 375 -T

PM 061 375 -T

PM 061 375 -T

Relay box, shielded, for backing pumps, 1-phase 7 A for TC 400/1200, 
TM 700 and TCP 350, M12

PM 071 284 -X

PM 071 284 -X

PM 071 284 -X

Содержание HiPace 400

Страница 1: ...PT 0210 BEN G 1604 OPERATING INSTRUCTIONS EN Translation of the original instructions HIPACE 400 Turbopump...

Страница 2: ...2 3 Drive 11 4 3 Range of application 12 5 Installation 13 5 1 Preparatory work 13 5 2 Set up 13 5 2 1 Earthquake safety 14 5 2 2 Use of a splinter shield or protection screen 14 5 2 3 Vibration dampe...

Страница 3: ...Maintenance replacement 30 7 1 Maintenance intervals and responsibilities 30 7 2 Replacing the operating fluid reservoir 30 7 3 Replacing the electronic drive unit 32 7 3 1 Rotation speed set value 32...

Страница 4: ...NSI Z 535 SEMI S1 ISO 3864 and DIN 4844 In this document the following hazard levels and information are considered HiPace 400 depending on the model Operating instructions Operating instructions Elec...

Страница 5: ...flange Vacuum flange of the backing pump Exhaust flange of the backing pump Electrical connection Sealing gas connection Venting connection Cooling water connection Prohibition of an action to avoid a...

Страница 6: ...nd maintenance of connected devices are described in detail in the operating instructions of the individual components For information on order numbers of components see Accessories Use original acces...

Страница 7: ...g maintenance and repairs or in case of reinstallation kg WARNING Risk of injury through falling objects When transporting vacuum pumps by hand there is a danger through loads slipping and falling dow...

Страница 8: ...mproper gas mode operation with improper high levels of insulated heat input operation in improper high magnetic fields venting with improper high venting rates use of the vacuum pump to generate pres...

Страница 9: ...y before connection Keep the original protective covers Always transport the turbopump in its upright position 3 2 Storage Close the flange openings by using the original protective covers Close furth...

Страница 10: ...ng plate 4 1 3 Variants HiPace 400 with TC 400 and 24 V DC 5 HiPace 400 with TC 400 and 48 V DC 5 4 1 4 Scope of delivery Turbopump with electronic drive unit Mating plug for the connection remote on...

Страница 11: ...he drive power au tomatically Depending on the application and the HiPace different cooling variants are selectable 4 2 2 Rotor bearing Hybrid bearing TurboDrag pump High vacuum side maintenance free...

Страница 12: ...ic field 6 mT Overvoltage category II Connection voltage TC depending on the variants 24 V DC 5 48 V DC 5 Remarks to ambient conditions The specified permissible ambient temperatures apply to operatio...

Страница 13: ...ible cleanliness when installing any high vacuum parts Un clean components prolong the pump down time All flange components must be grease free dust free and dry at installation The operating fluid re...

Страница 14: ...damper Fig 3 Example How to secure against shifting and tipping by external tremors Safety connection implementation each by the customer VACUUM CHAMBER Reduced volume flow rate in H2 He N2 Ar Splint...

Страница 15: ...rom the pipe system may be exerted on the fixed pump To avoid contamination via the fore vacuum line when using oil sealed backing pumps the fore vacuum flange should always point vertically downward...

Страница 16: ...rding to the drawing and with the component parts of the mounting kit 2 Use the required number of 16 claw clamps 3 Tighten the claw clamps crosswise in three steps 4 Tightening torque 5 15 25 2 Nm DA...

Страница 17: ...mm2 in all oper ating conditions 6 Tighten the hex screws crosswise in three steps 7 Tightening torque DN 160 5 10 16 1 Nm Stud screw and threaded hole Mind that the sealing surfaces are not damaged 1...

Страница 18: ...les The tensile strength of the flange material must be at least 270 N mm2 in all oper ating conditions 4 Tighten the hex screws crosswise in three steps 5 Tightening torque DN 160 10 20 38 3 Nm Stud...

Страница 19: ...counter flange 2 If used Insert protective screen or splinter shield with the clamping lugs downward into the high vacuum flange of the turbopump 3 Place the seal exactly in the hollow 4 Connect the f...

Страница 20: ...away the gas emission from the backing pump Observe all safety recommendations of the gas producer Fig 5 Connecting the backing pump 20 Fore vacuum connection 20a Backing pump 20 1 Centering ring 20...

Страница 21: ...ends to connect an appropriate earthing wire to derive applica tive interferences Fig 6 Installing the earthing connection 5 6 3 Power and electrical supply For voltage supply of the electronic drive...

Страница 22: ...the units listed below are connected with the preconfigured connection they are immediately ready for operation according to the factory settings It is possible to connect other accessories to do so s...

Страница 23: ...se of shut down or power failure The permissible connection pressure is max 1500 hPa absolute Unscrew the venting screw with seal ring from the venting connection Screw in the venting valve with seal...

Страница 24: ...the settings and control via the interfaces of the electronic drive unit Install the sealing gas supply e g inert gas via a connection adapter or on the inlet side G 1 8 of the control valve Sealing g...

Страница 25: ...eating jackets Plug in and fix the accessory s control lead to the corresponding accessory connection port on the electronic drive unit Default for the casing heating is accessory B2 Establish the mai...

Страница 26: ...ling water connection Socket connection Hose lines External diameter 8 mm Internal diameter 6 mm Cooling water quality filtrated mechanically clean optically clear no turbidity no sediments chemical l...

Страница 27: ...Operation via remote connection Operation via RS 485 and Pfeiffer Vacuum display and control units or PC Operation via field bus 6 3 Function description NOTICE Risk of destroying the pump by inputtin...

Страница 28: ...Operating instructions HPU Operating instructions Electronic drive unit TC 400 Switch on the supply voltage with switch S1 on the power supply or on the DCU 400 Settings are possible via interface RS...

Страница 29: ...ssible via interface RS 485 by using DCU HPU or PC 1 When mains power is restored the venting procedure is aborted Basic information for the rapid venting Venting of the vacuum chamber in two steps As...

Страница 30: ...umped media is possible Poisoning hazard through contact with materials that damage health In the case of contamination carry out appropriate safety precautions in order to pre vent danger to health t...

Страница 31: ...ee cloth Do not use any cleaning fluids Using tweezers insert the new Poroplast rods 9x Install the new operating fluid reservoir in the bearing mounting of the turbopump with the felt side oriented t...

Страница 32: ...redundant safety system for avoiding excess rotation speeds Adjust the parameter P 777 according to the pump type Alternatively If no display and control unit is available please use the SpeedCon fig...

Страница 33: ...eiffer Vacuum Service clean the turbopump completely Replace the operating fluid reservoir if necessary If necessary have the bearings replaced Take into account the total running time Installation an...

Страница 34: ...via interface RS 485 Please refer to operating instructions of the electronic drive unit Voltage drop in the cable too high Use a suitable cable Pump does not attain the final rotational speed within...

Страница 35: ...0 l s Leave electronic drive on the pump Close the flange openings by using the original protective covers If possible send pump or unit in the original packaging Sending of contaminated pumps or devi...

Страница 36: ...e when ordering accessories or spare parts Item Designation Order number Notes Pieces Order qty 7 Operating fluid reservoir PM 143 452 T incl Poroplast rods 1 8 Electronic drive unit TC 400 according...

Страница 37: ...entering ring stud screws PM 016 455 T Mounting kit for DN 100 ISO F including coated centering ring protec tion screen stud screws PM 016 457 T Mounting kit for DN 100 ISO F including coated centerin...

Страница 38: ...PM 071 142 X Control cable for pumping stations 0 7 m PM 061 675 AT PM 061 675 AT PM 061 675 AT Y Connector M12 to RS 485 P 4723 010 P 4723 010 P 4723 010 Y connector shielded M12 for accessories P 4...

Страница 39: ...75 kPa 10 0 01 1000 10 1 7 5 Torr mm Hg 1 33 1 33 10 3 133 32 1 33 0 133 1 1 Pa 1 N m2 mbar l s Pa m3 s sccm Torr l s atm cm3 s mbar l s 1 0 1 59 2 0 75 0 987 Pa m3 s 10 1 592 7 5 9 87 sccm 1 69 10 2...

Страница 40: ...ondensing 5 85 non condensing Protection category IP54 IP54 IP54 Connection pressure max for venting sealing gas valve 1500 hPa 1500 hPa 1500 hPa Drive power max 350 W 350 W 350 W Operating voltage 48...

Страница 41: ...06 5 230 5 239 208 M8 6x M8 6x 208 45 45 16 7 30 130 1 1 7 59 VV DN 25 ISO KF G 1 4 8 131 145 5 HV DN 100 ISO K 150 130 131 230 5 239 206 5 175 208 45 45 1 1 7 150 59 30 M8 6x VV DN 25 ISO KF G 1 4 8...

Страница 42: ...technical documentation is Mr Helmut Bern hardt Pfeiffer Vacuum GmbH Berliner Stra e 43 35614 A lar HiPace 400 Harmonised standards and national standards and specifications which have been ap plied...

Страница 43: ...are the only supplier of vacuum technology that provides a complete product portfolio COMPETENCE IN THEORY AND PRACTICE Benefit from our know how and our portfolio of training opportunities We suppor...

Отзывы: