Installation
25
●
When using a casing heating and a water cooling unit the temperature of the connect-
ed flange of the vacuum chamber must not exceed 120 °C.
●
The maximum permissible rotor temperature for the turbopump is 90 °C. If high tem-
peratures arise for process reasons, the radiated heat input must not exceed 4.2 W.
Install suitable screening sheets, if necessary (design information on request).
Bend open the outer heating jacket on the tensioning strap and place it sidewards on
to the cylindrical segment of the pump casing.
– Do not bend the heating straps!
– The heating jacket must seat completely on the casing segment.
Fix the heating jacket with the fixing screw on the casing.
– Observe the tightening torque for the fixing screw!
Table 2: Tightening torques for fixing screws of heating jackets
Plug in and fix the accessory’s control lead to the corresponding accessory connection
port on the electronic drive unit.
Default for the casing heating is "
accessory B2
".
Establish the mains supply for the relay box according to the accessory operating in-
structions.
CAUTION
Risk of burns
High temperatures arise when the turbopump or vacuum chamber are baked out. As a
result, there is a danger of burns from touching hot parts, even after the casing heating
is switched off!
Thermally insulate heating jacket, pump housing and vacuum chamber, if possible
during installation.
Do not touch heating jacket, pump casing and vacuum chamber during bake out.
Fig. 10: Connecting the heating jacket
4 Pump
casing
4a
Heating jacket
4b
Fixing screw
4c
Heating relay box
4d
Warning sticker
Fixing screw
Tightening torque
in cold condition
Tightening torque
during the heating-up
Singular retightening af-
ter the cooling down
M5
6 Nm
7 Nm
7 Nm
M6
11 Nm
12 Nm
12 Nm
H
4a
4d
4b
2x
4c
4