background image

21

9. Accessories 

When ordering accessories please be sure to state the full part number. Please use this list as an order form (by taking a copy).

D

Deessccrriippttiioonn

S

Siizzee

O

Orrddeerriinngg

C

Coom

mm

meennttss

N

Noo..

Dust separator 

SAS 90

PK Z60 503

incl. filter insert

Replacement filter

2 μm

PK E57 006-T

paper 

Replacement filter

5 μm

PK E57 010-T

polyester

Vacuum flange 

DN 40 ISO-KF / G 1 1/4" PK 101 035

stainless steel

O-ring

Ø

38x2,5

P 0920 064 E

Reducing intermediate piece

DN 50-40 ISO-KF

PF 140 054

aluminium

Reducing intermediate piece

DN 50-40 ISO-KF

PF 140 254 -X

stainless steel

Sintering filter for sealing gas port

G 1/8"

PR 003 505 -T

Magnetic valve TVF 005 for sealing gas and 
gas ballast inlet

G 1/8"

PM Z01 135

24 V/DC

Elbow union with orifice

G 1/8”

PR 003 578 -U

orifice 0,2 mm

Electronic drive and control unit TCP 2000

PR C01 000

Control panel 1 phase

Electronic drive and control unit TCP 2000

PR C01 001

Control panel 3 phases

Electronic drive and control unit TCP 2000

PR C01 002

Version with housing 1 phase

Electronic drive and control unit TCP 2000

PR C01 003

Version with housing 1 phases

Electronic drive and control unit TCP 2000 PB

PR C01 004

Control panel 1 phase

Electronic drive and control unit TCP 2000 PB

PR C01 005

Control panel 1 phase

Electronic drive and control unit TCP 2000 PB

PR C01 006

Version with housing 1 phase

Electronic drive and control unit TCP 2000 PB

PR C01 007

Version with housing 1 phase

Connection cable with terminal box

3m

PR 003 543 -T

other length on request

Extension for sensor cable

1m

PO 003 346 -X

Extension lead X2 for
cooling water monitor

Extension for sensor cable

3m

PO 003 347 -X

Extension lead X2 for
cooling water monitor

Содержание OnTool Booster 150

Страница 1: ...Translation of the original instructions Operating Instructions EN PU 0058 BEN 1 OnTool BoosterTM 150 Side Channel Pump with TCP 2000...

Страница 2: ...c Drive Unit TCP 2000 11 3 9 Using Sealing Gas 12 3 10 Pumping Of Vapors 13 3 11 Pumping Of Light Or Heavy Gases 13 4 Operations 14 4 1 Before Switching On The Pump 14 4 2 Switching The Pump ON 14 4 2...

Страница 3: ...between the pump and the TCP 2000 during operations When the vacuum flange is open disconnect the voltage supply to the TCP 2000 When working on the pump the vacuum flange should only be opened once t...

Страница 4: ...TE Danger of burns from touching hot parts WARNING Danger of an electric shock WARNING Danger of injury from rotating parts WARNING Danger of personal injury WARNING 1 2 Pictogram Definitions Danger o...

Страница 5: ...ax permissible intake pressure for continous operation 1000 mbar for N2 and air Max permissible vacuum chamber volume for loadlock applications 1 m 3 Improper Use The following are regarded as imprope...

Страница 6: ...zzles for the cooling water monitor and the cooling water connection input output including sealing rings Reducing nipple for the cooling water monitor Cooling water monitor Blank flange DN 50 ISO KF...

Страница 7: ...suitable transport straps or screw an eye bolt into the transport bores T and lift the pump with lifting bar Ensure even distribution of weight when lifting Danger of tilting WARNING WARNING 3 3 Sett...

Страница 8: ...ot fill when the pump is running and not in evacuated condition Unscrew both lubricant filler screws 31 taking care with the sealing Slowly fill in 24 ml of the accompanying lubricant into each lubric...

Страница 9: ...nclean components prolong the pumping time Fit a vacuum safety valve Accessory in the vacuum line This prevents the vacuum chamber being ventilated via the backing pump PLEASENOTE Cover and bolt down...

Страница 10: ...deposits collecting in the pump the cooling water must be filtered Minimum cooling water requirements Mechanically clean optically clear no turbidity no sediment chemically neutral Oxygen content max...

Страница 11: ...s a danger of an electric shock from touching the contacts For further details please refer to Operating Instructions PU 0056 BN for the Electronic Drive Unit TCP 2000 WARNING CAUTION U V W 95080402 0...

Страница 12: ...ugh between the suction chamber and the bearing chamber on the exhaust side This effects the following protection of the lubricant against contamination protection of the bearing when pumping vapors a...

Страница 13: ...the case of lighter gases the gas ballast operates as a carrier gas which promotes pumping of the process medium If gases other than air or nitrogen are used for the gas ballast please discuss such pl...

Страница 14: ...change of lubricant the contacts for monitoring the lubricating pump can open as a result of degassification In such cases as for other malfunctions the electronic drive unit switches off the pump PLE...

Страница 15: ...rocess has been completed allow the pump to continue running for about 30 minu tes with open gas ballast valve for operating fluid regeneration purposes CAUTION 4 4 Switching The Pump OFF Details rega...

Страница 16: ...ve unit defect Check ventilator function Cooling water monitor defective or not connected Check cooling water monitor The pump does not attain the final Dirty pump In serious cases inform Pfeiffer Vac...

Страница 17: ...ess related toxic gases and vapours can escape from the lubricant which may become comtani mated with harmful substances radioactive chemical etc Please request safety instruction data sheets for lubr...

Страница 18: ...position Do not fill when the pump is running and not in evacuated condition Unscrew both lubricant filler screws 31 taking care with the sealing Slowly fill in 24 ml of the accompanying lubricant int...

Страница 19: ...vely or radioactively cannot be accepted as a matter of principle Fill out the service request and the declaration on contamination Download the forms Service Request and Declaration on Contamination...

Страница 20: ...ant F3 Amount of lubricant for the lubricant reservoirs ml each 24 Cooling water consumption with water at 15 C l min 2 Cooling water temperature C 15 30 Permissible ambient temperature C 12 40 Weight...

Страница 21: ...Elbow union with orifice G 1 8 PR 003 578 U orifice 0 2 mm Electronic drive and control unit TCP 2000 PR C01 000 Control panel 1 phase Electronic drive and control unit TCP 2000 PR C01 001 Control pan...

Страница 22: ...22...

Страница 23: ...nsible for compiling the technical documentation is Mr Sebastian Oberbeck Pfeiffer Vacuum GmbH Berliner Stra e 43 35614 A lar OnTool BoosterTM 150 Guidelines harmonised standards and national standard...

Страница 24: ...e the only supplier of vacuum technology that provides a complete product portfolio Benefit from our know how and our portfolio of training opportunities We can support you with your plant layout and...

Отзывы: