L1
L3
L2
W4
W2
W3
W1
V4
V2
V3
V1
U4
U2
U3
U1
V
Fig. 21:
Double star circuit
Connect the three phase motor with double star circuit
► Connect the three phase motor according to the connection diagram.
L1
L3
L2
V
W4
W2
W3
W1
V4
V2
V3
V1
U4
U2
U3
U1
Fig. 22:
Delta connection
Connect the three phase motor with delta connection
► Connect the three phase motor according to the connection diagram.
L1
L3
L2
W4
W2
W3
W1
V4
V2
V3
V1
U4
U2
U3
U1
V
Fig. 23:
Star circuit
Connect the three phase motor with star circuit
► Connect the three phase motor according to the connection diagram.
5.12 Checking the direction of rotation
NOTICE
Motor damage from overheating
Limited fan cooling capacity, caused by incorrect rotation direction, causes the motor to overheat.
► Check the direction of rotation using the rotation direction arrow on the fan of the motor.
► If the rotation direction is incorrect, switch 2 of the 3 phases.
► When doing so, make sure that the air flow is sucked through the ventilation grille, and directed
over the motor to be cooled.