Installation and commissioning
8 - 3
●
Set main switch
3
at position "1".
●
In addition, on machines with hot air, turn regulator
1
, until the hot air pressure shown on
gauge
2
, is at least
0.2 bar
.
The hot-air pressure must not drop below
0.2 bar
!
If the hot-air pressure is too low, there is a risk of the heating rod burning out.
The heating therefore switches off automatically when the hot-air pressure is
too low.
8
.03
Switching the machine on/off
Fig. 8 - 03
1
2
Fig. 8 - 04
3