Adjustment
12 - 10
2
5
8
4
6
9
10
Fig. 12 - 08
54-020a
3
7
49-028a
1
12
.05.08
Clearance between presser foot and needle plate
Requirement
When hand lever
1
is raised there should be a clearance of
5 mm
between the presser
foot and the needle plate.
●
Unscrew the presser foot.
●
Screw on gauge foot
1
(part no. 61-111 639-20) and lower it down to touch the needle
plate.
●
Push out bolt
2
(screw
3
) and remove connection element
4
from the yoke of lever
5
.
●
By turning the balance wheel bring lever
6
to its furthest point of reversal.
●
Place feed dog adjustment gauge under the presser foot with the recess facing down.
●
Loosen screw
7
and push out bolt8.
●
Adjust presser foot (screw
8
) at the side so that the edge of the presser foot is parallel to
the bottom feed dog.