Adjustment
42
13
.06.03
Adjusting the top knife to the stationary knife
Requirement
Top knife
1
must bear with slight pressure sideways against the stationary knife.
Loosen the screws
2
and remove photo-cell bracket
3
.
Loosen screws
4
just enough to allow bracket
5
to be moved.
Re-position bracket
5
in sewing direction so that the top knife
1
is resting parallel on the
stationary knife with a slight pressure.
Tighten screws
4
.
The top knife
1
must move freely in the needle plate cutout.
The lug of the top knife
1
must not strike the stationary knife.
Turn the balance wheel. Top knife
1
must not touch any of the feed parts when in its bot-
tom position.
Carry out a cutting test by hand with thread chain and pieces of bridle tape. The knife
must cut perfectly across its entire cutting edge.
Refi t photo cell bracket 3 with screws 2 and position it according to see
Chapter 13.07
Setting the photocell.
Reinstall the compression spring
6
and the thread and ribbon clip
7
and tighten the screw
8
.
Reconnect the compressed air.
Machine switched on.
The thread and ribbon clamp 7 must lie parallel on the throat plate when the
solenoid valve is activated (adjust if necessary by reworking).