91
Adjustment
Fig. 13 - 22
111-029
0,2 mm
2
1
111-089
3
13
.24
Basic position of the button holder
(only on the PFAFF 3307-9/..)
Requirement
With the needle bar at b.d.c., there should be a distance of
0.2 mm
between button holder
1
and the needle shank.
●
Switch on the machine and set parameter "610" at value "1".
●
Adjust button holder
1
(screws
2
) in accordance with
the requirement.
●
Switch off the machine.
When tightening the screws, pin
3
must be in the centre of the hole.