Adjustment
46
7
.03
List of parameters
The operator has free access to the "
100
" parameters. Parameters "
2
00" - "800"
can only be changed after entering a code number and may only be changed by
authorised personnel.
Group
P
arameter
Description
S
et
ting range
S
et value
1
102
Reversing
OFF - ON
OFF
113
Beep tone for section change
OFF - ON
OFF
114
Max. speed forwards at each pedal positio
OFF - ON
OFF
2
201
Machine confi guration
9 = 487-918/15
10 = 5487-918/15
11 = 489-918/15
209
Fullness adjustment value (keyboard)
0 - 9
0
212
Not speed variation with change of fullness
OFF - ON
OFF
213
program interruption with pedal-position -
2
OFF - ON
OFF
3
301
Position
"Needle point at top edge needle plate"
(P320ED)
0 - 127
0
302
Position "take-up lever t.d.c."
487, 489
5487
0 - 127
113
107
303
Position "needle lowered"
487, 489
5487
0 - 127
0
24
60
304
Reversing position
0 - 127
113
4
401
Delay time "lift foot" (s)
0,01s - 1,5s
0,02s
402
Start delay after "lower foot" (s)
0,01s - 1,5s
0,15s
403
Thread cutting time (on the
5487
)
0,01s - 0,2s
0,15s
404
Time for cleaning thread monitor (s)
0,01s - 1,5s
0,25s
5
501
Maximum speed
487, 489
5487
100 - 5500
4800
5500
504
Speed soft start
100 - 5500
1500
505
Soft start stitches
0 - 15
0
Содержание 487-918/55
Страница 56: ...56 P320 ED P323 MS Circuit diagrams Version 20 09 07 91 191 525 95 Part 2...
Страница 57: ...57 91 191 525 95 Part 3 Version 20 09 07 Circuit diagrams P320 ED P323 MS...
Страница 58: ...58 P320 ED P323 MS Circuit diagrams Version 20 09 07 91 191 525 95 Part 4...
Страница 59: ...Note...