Troubleshooting

Fault Code Messages

Fault Code

No.

Description

2,E

01

Brake channel over current

2/EU

02

Brake resistor overload

2,

03

Output Over Current

,WWUS

04

Motor Thermal Overload (I2t)

29ROW

06

Over voltage on DC bus

89ROW

07

Under voltage on DC bus

2W

08

Heatsink over temperature

8W

09

Under temperature

(WULS

11

External trip

6&2E6

12

Optibus comms loss

)/WGF

13

DC bus ripple too high

3/266

14

Input phase loss trip

K 2,

15

Output Over Current

WK)OW

16

Faulty thermistor on heatsink

G$W$)

17

Internal memory fault (IO)

 )

18

4-20mA Signal Lost

G$W$(

19

Internal memory fault (DSP)

)3WF

21

Motor PTC thermistor trip 

)$1)

22

Cooling Fan Fault (IP66 only)

2K($W

23

Drive internal temperature too high

287)

26

Output Fault

$W)

41

Autotune Fault

6&)

50

Modbus comms loss fault

6&)

51

CAN comms loss trip

NOTE

 Following an over current or overload trip (1, 3, 4, 15), the drive may not be reset until the reset time delay has elapsed 

to prevent damage to the drive.

Содержание VDI-037-3E3-IP66

Страница 1: ...e l e c t r o n i c AC Converter VersiDrive i E3S IP66ODS Quick Start Manual Quality is our drive...

Страница 2: ...ersiDrive must be mounted in a vertical position only Installation should be on a suitable at ame resistant surface Do not mount ammable material close to the drive Refer to Technical Data and ensure...

Страница 3: ...ve Below Y Either Side mm in mm in All Frame Sizes 200 7 87 10 0 39 NOTE Typical drive heat losses are approximately 3 of operating load conditions Above are guidelines only and the operating ambient...

Страница 4: ...egulations Maximum dimensions are given in the Rating Tables section of this Quick Start Guide Install the Wiring L1 L L3 EMC Gland plate can be removed for installation L2 N U V W 1 2 3 4 5 6 7 8 9 1...

Страница 5: ...he line side of this equipment and shall be rated 480Volt phase to ground 480 Volt phase to phase suitable for over voltage category iii and shall provide protection for a rated impulse withstand volt...

Страница 6: ...ed set P 16 to the correct format NOTE Additional functions are possible refer to the online documentation for further information Motor Thermistor Connection Where a motor thermistor is to be used it...

Страница 7: ...econd The display will show the motor power kW If P 10 0 pressing the Navigate key for 1 second will display the motor speed RPM Changing Parameters 67R3 3 3 3 3 Press and hold the Navigate key 2 seco...

Страница 8: ...al Keypad Control 3 Modbus Network Control 4 Modbus Network Control 5 PI Control 6 PI Analog Summation Control 7 CAN Control 8 CAN Control 9 Slave Mode NOTE When P 12 1 2 3 4 7 8 or 9 an enable signal...

Страница 9: ...ly Closed operation is supported depending on Index 2 setting The drive will remain in Fire Mode until disabled or powered off P 31 Keypad Start Mode Select 0 7 1 0 Minimum Speed Keypad Start 1 Previo...

Страница 10: ...owing procedure can be used 1 The motor must be correctly connected to the drive and safe to operate before using this procedure 2 Ensure the motor rated voltage P 07 and current P 08 have been correc...

Страница 11: ...Maximum Cable Size Output Current Recommended Brake Resistance Non UL UL mm AWG A 110 115 10 V 1 Phase Input 3 Phase Output 1 0 37 0 5 8 5 16 15 8 8 7 0 2 0 75 1 12 5 16 15 8 8 10 5 100 200 240 10 V 1...

Страница 12: ...13 DC bus ripple too high 3 266 14 Input phase loss trip K 2 15 Output Over Current WK OW 16 Faulty thermistor on heatsink G W 17 Internal memory fault IO 18 4 20mA Signal Lost G W 19 Internal memory...

Страница 13: ...Phone 49 0 9189 4147 0 Fax 49 0 9189 4147 47 eMail mail peter electronic com PETER electronic GmbH Co KG Bruck cker 9 D 92348 Berg www peter electronic com...

Отзывы: