refer to the APP manual
to download the APP:
Perry Timer
Once the Wi-Fi clock switch is
installed in an electrical panel,
inaccessibility to the terminals
without special tools must be
guaranteed.
ELECTRICAL CONNECTIONS
Description of terminals:
230V~ power supply
terminal 5 =
(Neutral)
N
terminal 10 =
(Line)
L
relay (C1)
terminal N° 1 = NO
(normally open contact)
terminal N° 2 = C
(common)
terminal N° 3 = NC
(normally closed contact)
Note: potential-free relay changeover contacts.
The electrical connections
must only be implemented
after having disconnected the
230V~ power supply.
1 2 3 4 5
6 7 8 9
10
C1
L
N
230 Vac
N
L
Wiring diagram
to connect the Wi-Fi device
E.g.: lamp
CONTROLS AND SIGNALS
Red relay status LED
indicates whether the relay is on or off.
When the relay is ON, the LED will be on;
when the relay is deactivated, the LED
will be off.
The button to manually control
the Wi-Fi time switch
- quick press:
command to switch the relay
status (ON / OFF)
-
pressed for 5 s
(rst switch-on) command to
search for a Wi-Fi network to
connect to.
-
pressed for 5 s
(device already connected to
the network) RESET command.
The blue status LED of the Wi-Fi network
Waiting to connect
to the Wi-Fi network
Device status
LED signal
ashing fast
off
Connected to the Wi-Fi
network
Problems with the Wi-Fi
network
xed
RESET
OPERATION WITH NO POWER
5
RESET:
press and hold the button
at the front for 5 seconds
To reset the Wi-Fi time switch to the factory settings, run the Reset function by
keeping the button on the front of the Wi-Fi time switch pressed for 5 seconds.
IMPORTANT: the time switch
, all
loses the association with the APP
programming is deleted and the device is set back to the factory default
settings.
Note: it will also be possible to delete the programming and/or association of
the device from the APP (see APP instructions).
IMPORTANT! It is recommended for the installer or expert user
to perform the RESET as this deletes any previous settings
and programs.
If the 230V~ power is disconnected (e.g. a blackout), the time switch disables the relay; the current date
and time are kept updated by the reserve charge of over 72 hours.
The language, programs and all previously entered settings are saved in a permanent memory.
If power is interrupted for more than 72 hours, the current date and time update cannot be guaranteed.
When power and the internet connection return, the current date and time will be automatically updated.
SIMPLIFIED EU DECLARATION OF
CONFORMITY
The manufacturer declares that the type of radio
equipment indicated below complies with
Directive 2014/53/EU (RED).
The full text of the EU declaration of conformity is
available at the address shown on the label:
Via MILANESE, 11 - 22070 VENIANO (Como)
ITALY - www.perry.it
Tel. +39-031-8944.1 Fax +39-031-931848
1IOIOWF02
V001
PERRY ELECTRIC S.r.l.
Manufacturer, Fabricat, Fabrikant, Fabbricante, Fabricante:
Type, T
, Tipo:
ypen
http://www.perry.it/it/dichiarazioni.aspx
Series, serie:
Programmable even without
an internet connection
using a shared Wi-Fi network
ROUTER
IMPORTANT!
the
must be carried out in the
FIRST CONNECTION
presence of a Wi-Fi network connected to the Internet.
4
EN
INTERNET
Wi-Fi
CONNECTION OF THE Wi-Fi DEVICE TO THE APP
Log in to the App with the personal credentials. If you do not have the credentials, register (see the APP manual)
Note: in case of problems with the Wi-Fi network, it will also be possible to associate the device to the APP using the AP mode
(see description in the APP manual)
Follow the procedure of the APP step-by-step and associate the Wi-Fi time switch to the App: «Add device»
Once the association of the Wi-Fi device has been conrmed, proceed with the programming as described in the APP manual.
INSTALLATION: system set