SYMBOLS AND MARKINGS

The symbols listed in the table below may appear on the device or its labeling:

Consult Instructions for Use

Type BF Applied Part

Catalog Reference Number

Temperature Limitation

Manufacturing Lot Number

 

AC

AC

Serial Number

 

DC

DC

Manufacturer

Ingress Protection Rating (Drip 

Proof)

Caution

Federal Law (USA) restricts this 

device to sale by or on the order of 

a physician

Date of Manufacture

Warning

Single Patient Use

Humidity

Instructions for Use

Do not use if package is open or 

damaged

DO NOT USE IF PACKAGE IS OPEN OR DAMAGED

Non sterile

Keep dry

Expiration

Pressure

WARNING: This product can expose 

you to chemicals including acryloni-

trile, which is known in the state of 

California to cause cancer. For more 

information, go to www.p65warnings.

ca.gov

INCLUDED WITH THE SYSTEM

The O

2

asis Humidifier comes with the following parts:

NOTE:

 If any of the items listed above are missing or damaged, please contact 

your care provider, licensed distributor, or O2asis Customer Service.

DEVICE OVERVIEW AND FEATURES

The O

2

asis personal humidifier is used with low flow oxygen therapy to provide 

moisture and heat to the oxygen stream. This greatly increases the comfort level 
of the oxygen therapy as oxygen is often very dry and can lead to discomfort.

Pressure

WARNING: This product can expose 

you to chemicals including acryloni-

trile, which is known in the state of 

California to cause cancer. For more 

information, go to www.p65warnings.

ca.gov

• O2asis Humidifier Base and Water Well 

Consumable Cartridge pre-installed    
• Power Supply
• O2asis Humidifier Adult Cannula
• Living with an O2asis Humidifier 

Pamphlet 
• Water Fill Pump

• Quick Start Guide
• Reorder Card
• User Guide
• Replacing Water Well Guide

PP-19-1 REV. 15

Содержание O2asis

Страница 1: ...Personal Humidifier USER GUIDE PP 19 1 REV 15...

Страница 2: ...und to be defective within the stated warranty period Should the O2asis base unit or the replacement water well fail prematurely the replacement base unit is warranted for the remainder of the origina...

Страница 3: ...djusting the Heat Level 13 Pediatric Patients 13 Use Without Electrical Power 14 Replacing the Water Well Consumable Cartridge 15 Checking for an empty Water Well 17 Cleaning and Disinfection 18 Regul...

Страница 4: ...the power cord in a way that will avoid anyone tripping or anything otherwise interfering with it Do not position the device in a way that would make it difficult to access the power supply connection...

Страница 5: ...er Do not attempt to use with or connect to other medical equipment This device is not intended for connection to a medical pipeline This device is not intended for use with patients whose upper airwa...

Страница 6: ...ryloni trile which is known in the state of California to cause cancer For more information go to www p65warnings ca gov INCLUDED WITH THE SYSTEM The O2asis Humidifier comes with the following parts N...

Страница 7: ...wer Cord Connector The connector that accepts the male connector at the end of the power cord 6 Heated Line The heated tube attached to the Water Well cartridge that heats the oxygen to prevent water...

Страница 8: ...ns Heated Line Power Levels Water Heater Temperature Levels Water Heater power turned off when Heated Line is not detected LED Indicator Lights 3 LED Indicator Lights low medium high User Interfaces T...

Страница 9: ...e For additional reservoir durations please refer to the Performance section of this manual Note The device will detect when the Water Well is empty and will shut down The three LED lights will flash...

Страница 10: ...o prevent over filling the pump should not be used while the Water Well is disconnected from the Base Unit Confirm that the electrical port is dry and reattach the device to an electrical outlet If th...

Страница 11: ...ment Note Make sure that the Water Well consumable cartridge is securely latched to the base unit before plugging in the power cord Note The O2asis Humidifier device will continue to humidify the airf...

Страница 12: ...steps Warning Use only the cannula included with the device Use of other cannulas can degrade the performance of the device 1 Remove the cannula from its plastic bag 2 Connect the tube end to the conn...

Страница 13: ...ed oxygen flow as shown in the table below 2 Above 2lpm of oxygen flow begin your oxygen therapy on the first level of heat When the device receives power the left most LED light will illuminate signi...

Страница 14: ...in Adjusting the Heat Level sec tion of this document Condensation Regularly check for visual condensation in the cannula If excessive amounts of condensation are present reduce the heat setting to t...

Страница 15: ...age device To replace the Water Well consumable cartridge complete the following steps 1 Unplug the power adapter cord from the latch side of the device 2 Unplug the oxygen source line from the oxygen...

Страница 16: ...ging 8 Insert the non port side of the cartridge into the button side of the base and push in until the cartridge sits flush with the base 9 Swing the base latch up and snap it onto the cartridge to l...

Страница 17: ...d can become contaminated with bodily fluids If visible contamination is present or performance degradation is suspected dispose of and replace the Water Well consumable cartridge Warning Do not touch...

Страница 18: ...oap Wipe all exterior surfaces If visible soil is present use a wetted soft nylon bris tle brush to remove visible soil paying close attention to seams and crevices in the device Wipe again with dish...

Страница 19: ...ganic solvents or abrasive cleaners These types of cleaners may create toxic gasses when heated and may damage the device Warning Water fill pump is intended for single patient use only The Water Fill...

Страница 20: ...hysical Dimensions 187 x 102 x 30mm 7 4 x 4 0 x 1 2 in Not including 1118mm 44 in long heated line Weight 0 7 lbs 65lbs 295 g empty 10 95 lbs 430 g full Distilled water reservoir approx capacity 135 m...

Страница 21: ...ion This device is an US FDA cleared Class II medical device This device is considered an IEC Class II continuous operation ordinary equipment device The heated line with cannula is considered an IEC...

Страница 22: ...w Rate lpm liters per minute Leakages ml milliliters Oxygen Supply Flow Rate Range 0 5 lpm to 6 lpm Maximum Oxygen supply flow rate 6 lpm ESTIMATED HUMIDIFICATION OUTPUT Dry Oxygen Flow Rate Heat Sett...

Страница 23: ...Warning Portable RF communications equipment including peripherals such as antenna cables and external antennas should be used no closer than 30 cm 12 inches to any part of the O2asis Humidifier Syst...

Страница 24: ...domestic purposes Harmonic emissions IEC 61000 3 2 Class A Voltage fluctuations flicker emissions IEC 61000 3 3 Complies Immunity Electromagnetic Immunity The O2asis Humidifier is intended for use in...

Страница 25: ...io bands 10 V m The O2asis Humidifier is suitable for the electromagnetic environment of typical homes commercial or hospital settings DISPOSAL Base Unit This device should be disposed of separately f...

Страница 26: ...snug If the device still does not provide the proper air flow please contact the care provider licensed distributor or O2asis to return the device Problem Possible Cause Action to Take The temperatur...

Страница 27: ...ng comfort anymore please purchase a new Water Well to restore full comfort Problem Possible Cause Action to Take The device does not seem to be operating correctly You accidentally spilled water onto...

Страница 28: ...1001 New Hampshire Ave Lakewood NJ 08701 USA Toll Free 1 800 337 3762 www o2asishumidifier com...

Отзывы: