Copyright © 2021 Perma Pure, LLC

Reproduction, adaptation, or translation in whole or in part in any form or medium without the 

express written consent of Perma Pure, LLC. is prohibited.  This documentation is intended for 

informational use only.

TRADEMARKS

O2asis™ is a registered trademark of Perma Pure, LLC.

All other trademarks are the property of their respective owners

WARRANTY

The O2asis personal humidifier is designed for use with low flow oxygen delivery systems to 

provide warmth and humidification to patients. Under normal operating conditions, Perma Pure 

will warrant the base unit to be free from defects of workmanship or materials for a period of 

one - (1) year, and the replacement water-well unit for a period of thirty - (30) days from the date 

of receipt provided that the unit is properly operated and maintained in accordance with Perma 

Pure’s operating instructions. Based on Perma Pure’s product evaluation, Perma Pure’s sole obli-

gation under the foregoing warranty is limited to making replacements, repairs or issuing credit 

for equipment found to be defective within the stated warranty period. Should the O2asis base 

unit or the replacement water well fail prematurely, the replacement base unit is warranted for 

the remainder of the original base unit warranty period, or the replacement water well is warrant-

ed for the remainder of the original water well warranty period. This warranty extends only to the 

buyer purchasing the equipment directly from Perma Pure or through Perma Pure’s designated 

distributors and/or agents as new equipment. 

Other replacement parts, consumables, and routine maintenance items are excluded from this 

warranty. Perma Pure shall not be liable to the purchaser or other persons for incidental or 

consequential damages or equipment that has been subject to abuse, misuse, misapplication, 

alteration, negligence or accident.

PATENTS

Covered by U.S. patent: 11071842
Other patents pending

CONTACT INFORMATION

Please contact your care provider, licensed distributor, or Perma Pure if you have trouble setting 

up or using the O2asis device. Should you need to contact Perma Pure directly, please use the 

following contact information: 

Perma Pure LLC

1001 New Hampshire Ave

Lakewood, NJ 08701 USA

Toll Free: 866-334-2447

www.o2asishumidifier.com

PP-19-1 REV. 15

5020967

MEDICAL 

ELECTRICAL 

EQUIPMENT

Содержание O2asis

Страница 1: ...Personal Humidifier USER GUIDE PP 19 1 REV 15...

Страница 2: ...und to be defective within the stated warranty period Should the O2asis base unit or the replacement water well fail prematurely the replacement base unit is warranted for the remainder of the origina...

Страница 3: ...djusting the Heat Level 13 Pediatric Patients 13 Use Without Electrical Power 14 Replacing the Water Well Consumable Cartridge 15 Checking for an empty Water Well 17 Cleaning and Disinfection 18 Regul...

Страница 4: ...the power cord in a way that will avoid anyone tripping or anything otherwise interfering with it Do not position the device in a way that would make it difficult to access the power supply connection...

Страница 5: ...er Do not attempt to use with or connect to other medical equipment This device is not intended for connection to a medical pipeline This device is not intended for use with patients whose upper airwa...

Страница 6: ...ryloni trile which is known in the state of California to cause cancer For more information go to www p65warnings ca gov INCLUDED WITH THE SYSTEM The O2asis Humidifier comes with the following parts N...

Страница 7: ...wer Cord Connector The connector that accepts the male connector at the end of the power cord 6 Heated Line The heated tube attached to the Water Well cartridge that heats the oxygen to prevent water...

Страница 8: ...ns Heated Line Power Levels Water Heater Temperature Levels Water Heater power turned off when Heated Line is not detected LED Indicator Lights 3 LED Indicator Lights low medium high User Interfaces T...

Страница 9: ...e For additional reservoir durations please refer to the Performance section of this manual Note The device will detect when the Water Well is empty and will shut down The three LED lights will flash...

Страница 10: ...o prevent over filling the pump should not be used while the Water Well is disconnected from the Base Unit Confirm that the electrical port is dry and reattach the device to an electrical outlet If th...

Страница 11: ...ment Note Make sure that the Water Well consumable cartridge is securely latched to the base unit before plugging in the power cord Note The O2asis Humidifier device will continue to humidify the airf...

Страница 12: ...steps Warning Use only the cannula included with the device Use of other cannulas can degrade the performance of the device 1 Remove the cannula from its plastic bag 2 Connect the tube end to the conn...

Страница 13: ...ed oxygen flow as shown in the table below 2 Above 2lpm of oxygen flow begin your oxygen therapy on the first level of heat When the device receives power the left most LED light will illuminate signi...

Страница 14: ...in Adjusting the Heat Level sec tion of this document Condensation Regularly check for visual condensation in the cannula If excessive amounts of condensation are present reduce the heat setting to t...

Страница 15: ...age device To replace the Water Well consumable cartridge complete the following steps 1 Unplug the power adapter cord from the latch side of the device 2 Unplug the oxygen source line from the oxygen...

Страница 16: ...ging 8 Insert the non port side of the cartridge into the button side of the base and push in until the cartridge sits flush with the base 9 Swing the base latch up and snap it onto the cartridge to l...

Страница 17: ...d can become contaminated with bodily fluids If visible contamination is present or performance degradation is suspected dispose of and replace the Water Well consumable cartridge Warning Do not touch...

Страница 18: ...oap Wipe all exterior surfaces If visible soil is present use a wetted soft nylon bris tle brush to remove visible soil paying close attention to seams and crevices in the device Wipe again with dish...

Страница 19: ...ganic solvents or abrasive cleaners These types of cleaners may create toxic gasses when heated and may damage the device Warning Water fill pump is intended for single patient use only The Water Fill...

Страница 20: ...hysical Dimensions 187 x 102 x 30mm 7 4 x 4 0 x 1 2 in Not including 1118mm 44 in long heated line Weight 0 7 lbs 65lbs 295 g empty 10 95 lbs 430 g full Distilled water reservoir approx capacity 135 m...

Страница 21: ...ion This device is an US FDA cleared Class II medical device This device is considered an IEC Class II continuous operation ordinary equipment device The heated line with cannula is considered an IEC...

Страница 22: ...w Rate lpm liters per minute Leakages ml milliliters Oxygen Supply Flow Rate Range 0 5 lpm to 6 lpm Maximum Oxygen supply flow rate 6 lpm ESTIMATED HUMIDIFICATION OUTPUT Dry Oxygen Flow Rate Heat Sett...

Страница 23: ...Warning Portable RF communications equipment including peripherals such as antenna cables and external antennas should be used no closer than 30 cm 12 inches to any part of the O2asis Humidifier Syst...

Страница 24: ...domestic purposes Harmonic emissions IEC 61000 3 2 Class A Voltage fluctuations flicker emissions IEC 61000 3 3 Complies Immunity Electromagnetic Immunity The O2asis Humidifier is intended for use in...

Страница 25: ...io bands 10 V m The O2asis Humidifier is suitable for the electromagnetic environment of typical homes commercial or hospital settings DISPOSAL Base Unit This device should be disposed of separately f...

Страница 26: ...snug If the device still does not provide the proper air flow please contact the care provider licensed distributor or O2asis to return the device Problem Possible Cause Action to Take The temperatur...

Страница 27: ...ng comfort anymore please purchase a new Water Well to restore full comfort Problem Possible Cause Action to Take The device does not seem to be operating correctly You accidentally spilled water onto...

Страница 28: ...1001 New Hampshire Ave Lakewood NJ 08701 USA Toll Free 1 800 337 3762 www o2asishumidifier com...

Отзывы: