Perlight Solar PLM-OM Series Installation Manual
12
www.perlight.com
V.01.2022 A1.0
Solar Mounting Systems
2400Pa Wind Load
2400Pa Snow Load
5400Pa Wind Load
3800Pa Snow Load
Fig.:3 Use Four Clamps
Fig.: 4 Use Four Clamps on Short Side and Two
Clamps on Long Side
Fig.: 5 Use Four Clamps
Fig.:6 Use Six Clamps
Module mounting clamps must not come into contact with the front glass and must not
deform the frame. Module clamps should not cause shadowing effects. It is not permitted to
modify the module frame under any circumstances. Recommended distance between two
modules is 5mm considering linear thermal expansion of the module frames.
Clearance between the module frame and mounting surface may be required to prevent the
junction box from touching the surface, and to circulate cooling air around the back of the
module.