Models
Temp
Control
Type
Set Point
(F)
Set Point
Range (F)
Hysteresis
(Air Temp)
Offset
Delay
Display
Defrost Type
Timing
Fan Delay
Post Defrost
HC48RW,
HC48WW, 2nd
Compartment
Digital
54
40-68
2
0
20
Air
Temp
N/A
N/A
N/A
HP48WO-S,
HP48WW-S,
1st
Compartment
Digital
43
40-68
8
10
20
Air
Temp
Programmed
12 Hrs
30 Mins
N/A
HP48WW-S,
2nd
Compartment
Digital
54
40-68
2
0
20
Air
Temp
N/A
N/A
N/A
NOTE:
Offset is the difference between the temperature that is actually being sensed and what is displayed to ensure
proper product temperatures.
Example: Set point 34, 6, controller needs to sense 28F before the unit will turn off.
Delay:
Control has a programmed time delay on temperature rise to show a stabilized temperature within the
refrigerated space.
Example: Set point 34F, unit cycles off, consumer opens the door, rather than have the temperature immedi-
ately shoot-up, it is delayed and will continue to show 34F until the delay time elapses. Meanwhile the
controller is sensing actual temperature and will turn on when it senses set point plus hysteresis.
Return to
Residential Refrigeration
and Front Venting Commercial Refrigeration
Service Manual
Electrical System Repair Instructions
Page 8-29