PROBLEM
CAUSE
SOLUTION
Refrigerator does not run. No power to the unit.
Check circuit protection devices. Fuses,
breakers, GFI).
Restore power to unit.
Refer to information plate. See
.
Incorrect control settings or faulty control. Return to factory settings (see
Refrigerator is too warm.
Power
No power to unit.
Check outlet for voltage.
Check power cord connection to machine
compartment harness.
Incorrectly wired internal wiring connec-
tions.
Verify wiring per wiring diagram. See
.
Reconnect wires if needed.
Fans
Evaporator fan is not running.
Refer to
Evaporator fan is not running
Coils
Evaporator coil has iced over.
Remove ice. See
Condensing coil is not clean.
Clean with soft brush and vacuum.
Fins are bent or damaged.
Straighten fins.
Control
No power to control.
Refer to
Control not functioning
Control is not calling for cooling.
Refer to
Control not functioning
Return to
Residential Refrigeration
and Front Venting Commercial Refrigeration
Service Manual
3.0
Trouble Shooting Guide
Refrigeration System
Use this diagnostic guide to identify issues and to locate applicable instructions within this service manual.
This diagnostic guide can be used for any of Perlick’s Residential and Front Venting Commercial Series Re-
frigeration Products.
ELECTROCUTION HAZARD!!
Never attempt to repair or perform maintenance
on the unit until the Main electrical power has
been disconnected.
Troubleshooting Guide - Refrigeration System
Page 3-1