Return to
STEP 1.
STEP 2.
STEP 3.
STEP 4.
STEP 5.
STEP 6.
STEP 7.
STEP 8.
STEP 9.
STEP 10.
STEP 11.
STEP 12.
STEP 13.
STEP 15.
STEP 17.
STEP 18.
STEP 19.
STEP 21.
Residential Refrigeration
and Front Venting Commercial Refrigeration
Service Manual
Turn off the CO
2
, either at the CO
2
cylinder or at
the air distributor.
Remove tapping device (keg coupler) from the
barrel.
If tapping device contains a check ball, insert check
ball lifter into the bottom of the coupler (Perlick
Low Profile Coupler does not contain a check ball).
Place tapping device into a small bucket.
Using a spanner wrench, remove the beer faucet
from the dispensing head.
Fill cleaning pump with warm water.
Attach cleaning pump jar connector with washer
to where faucet was removed from dispensing
head.
Pump the warm water through the system to re-
move all remaining beer from the system. Empty
tapping device bucket and rinse out. Place tapping
device back into the bucket.
Fill cleaning pump jar with water and cleaning
chemical per the recommendations on the cleaning
chemical container.
Pump cleaning solution into system, leaving about
a 1/2 the solution in the cleaning pump jar.
Let stand 15 minutes, then pump remaining
solution through the system.
Using a cleaning brush, clean the exterior
surfaces of the tapping device and rinse with
clean fresh water
Rinse out cleaning pump jar with fresh water
STEP 14.
Fill cleaning pump jar with clean warm water and
pump entire jar through the system
Repeat STEP 13 using clean cold water
STEP 16.
During the 15 minutes that the solution is in
the system, mix a small container with water
and cleaning chemical per the instructions on the
cleaning chemical container and disassemble the
faucet per faucet manufacturers recommenda-
tions and let soak in solution
Using cleaning brush, clean the components of
the faucet
Rinse all components of the faucet in clean fresh
water. Check all seals on the faucet for wear and
replace if necessary
Reassemble faucet
STEP 20.
Remove cleaning pump jar from dispensing
tower connection and reinstall faucet using
spanner wrench to tighten properly
Turn on CO
2
and tap new keg
Refrigeration System Repair Instructions
Page 7-14