Perle IDS-108FPP (XT)  

Unmanaged 10/100 PoE/PoE+ 
Ethernet Switches with Fiber Ports 

 

 

         

 

            P/N 5500341-10 (Rev I) 

Installation Guide 

Содержание IDS-108FPP series

Страница 1: ...Perle IDS 108FPP XT Unmanaged 10 100 PoE PoE Ethernet Switches with Fiber Ports P N 5500341 10 Rev I Installation Guide...

Страница 2: ...in various copper and fiber configurations see table below The fiber ports can be either single mode SM or multimode MM depending on the model selected and can operate over different wavelengths and d...

Страница 3: ...puts 18 57 VDC Rugged high strength IP30 aluminum case Industrial temperature models Din rail or wall panel mounting Note In this guide the various models will be referred to as the IDS 108FPP Getting...

Страница 4: ...IDS 108FPP Installation Guide 4 Front View of IDS 108FPP 8 port RJ 45...

Страница 5: ...IDS 108FPP Installation Guide 5 Front View of IDS 108FPP with one or two fiber ports...

Страница 6: ...e IDS 108FPP with two ST fiber ports installed Top view of the IDS 108FPP The IDS 108FPP switch has two power inputs that can be connected simultaneously If one power source fails the other source act...

Страница 7: ...9 10 Port 9 10 Fiber Green LED On Link up Flashing Link up and Ethernet activity detected Off Link down Ethernet Port Status Port Link Speed Green and Yellow LEDs Port Link Green LED On Link up Flash...

Страница 8: ...IDS 108FPP Installation Guide 8 Views for the IDS 108FPP...

Страница 9: ...IDS 108FPP Installation Guide 9...

Страница 10: ...he DIN rail fits into the slot on the top of the DIN rail clip just below the DIN rail hook and behind the spring 3 While pushing down on the unit to compress the spring rotate the bottom of the IDS 1...

Страница 11: ...ve the screws into the wall leaving about 2 mm of the screw protruding from the wall to allow room for sliding the wall mount panel between the wall and the screws 5 Fix the screws to the wall and the...

Страница 12: ...g of the equipment is performed by trained and qualified personnel and that the installation complies with all local and national electrical codes This unit should be installed in a restricted access...

Страница 13: ...only WARNING EXPLOSION HAZARD Do not disconnect equipment unless power has been removed or the area is known to be non hazardous WARNING EXPLOSION HAZARD Substitution of any components on this switch...

Страница 14: ...ews 0 51Nm torque 6 Ensure the wires are securely fastened 7 Re insert the Terminal block connector if removed 8 Turn on power source 9 Check that the P1 LED is On 10 If desired connect P2 power sourc...

Страница 15: ...cable Connect the copper cables from each TP port RJ 45 on the IDS 108FPP switch to Ethernet enabled devices See below for 8 pin RJ 45 pinouts Remaining pins not used Fiber Port Cabling Requirements...

Страница 16: ...the IDS and the other cable end to a fiber compliant device If you are making your own fiber cables remember that the RX on one side needs to go to TX on the other side and vice versa See diagram belo...

Страница 17: ...See fiber specifications PoE PoE ports Up to 30 Watts per port switch RJ 45 driving up to four class 4 IEEE 802 3at type 2 PDs Alternative B ALT B MDI X pinouts Power over Pins 4 5 Positive and 7 8 N...

Страница 18: ...FCC Part 15 Class A CISPR22 2008 EN55022 2010 Class A CISPR 24 2010 EN55024 2010 Note The safety certifications apply only to ambient temperatures under 60 C 140 F However the IDS 108FPP can function...

Страница 19: ...RX 1310 Min 8 Max 3 Min 22 Max 3 14 IDS 108FPP S2xx40 XT SC ST SM duplex 40 km 24 9 miles TX 1310 RX 1310 Min 3 Max 5 Min 23 Max 3 20 IDS 108FPP S1SC40U SC SM simplex 40 km 24 9 miles TX 1310 RX 1490...

Страница 20: ...9 miles TX 1550 RX 1310 Min 5 Max 0 Min 34 Max 3 20 IDS 108FPP DS2xx80 2 x SC SC ST SM duplex 80 km 49 7 miles TX 1550 RX 1550 Min 5 Max 0 Min 34 Max 3 29 IDS 108FPP DS2xx120 2 x SC SC ST SM duplex 1...