4012/16TESI (MINNOX) WIRING DIAGRAM WITH CAV STARTER AND PROTECTION
SWITCHES
46
4012/16 Gas, February 1998
Key
(Fig. 35)
1.
Oil press switch
2.
220
Ω
5w resistor
3.
Charging alternator
4.
Repeater relay
5.
Start motor
6.
‘Start relay
7.
Engine fault switches left/right banks
8.
Water temp.
9.
Oil press
10. All fault switches close on a fault. One
side of all fault switches are identical. For the
engine to run, immediately on depressing
start button, Gov+ must be fed 24 volt +ve. To
stop the engine break this +ve.
11. Left/right manifold high gas pressure
detector switches
12. Pick-up sensing on flywheel
13. Left/right manifold switch gauges for
manifold out of balance protection
14. Switch speed 700 rpm
15. Switch overspeed
16. Two switch speed unit
Fig. 35
Содержание 4012TESI Series
Страница 1: ...TSL4187E Issue 1 February 1998 User s Handbook Perkins 4012 and 4016 Gas 4012TESI 4016TESI...
Страница 7: ...4012TESI MINNOX 4012TESI MINNOX...
Страница 8: ...4016TESI MINNOX 4016TESI MINNOX...
Страница 49: ...4012 4016 GAS ENGINES FAULT TRACING CHART 4012 16 Gas February 1998 45 Fig 34...
Страница 57: ...1998 Perkins Engines Company Limited All Rights Reserved...