PERI InSite Construction -
Data Acquisition System
Instructions for Installation and Use - Technical Cabinet with Main Unit and Nodes – Preliminary Draft –
Unit on, scheduled to start
When the Main Unit has a measurement, session scheduled to start in the future but has not
started yet the red LED lamp indicator flashes for 0.2 seconds every 2 seconds.
UNIT ON SCHEDULED TO START
RED LED
0.2 s
2 s
0.2 s
2 s
0.2 s
2 s
. . .
●
○
●
○
●
○
No measurement data is stored or transferred when the Main Unit is in the modes
described in sections 3.7.2.3.1 and 3.7.2.3.2. Make sure a measurement session is
active in order to collect and store data.
Connecting to the Internet
When the Main Unit attempts to establish a connection to the internet, the green LED lamp
indicator flashes at a rapid rate. Connections are established during the following
circumstances:
•
Scheduled connections according to the settings made on the Web Portal,
(the Connection Rate, CR), normally every five minutes.
•
When the unit has just been turned on or off in order to convey this information to the
Web Portal.
•
If a user performs a Force Connect, FC, on a paired Node within the radio range of the
Main Unit or if a Force Connect, FC, is performed on the Main Unit according to the
procedure described in section 3.7.2.1.3.
CONNECTING TO THE INTERNET
GREEN LED
0.2 s
0.2 s
0.2 s
0.2 s
0.2 s
0.2 s
. . .
●
○
●
○
●
○
A connection to the Internet can be instigated either by performing a Force Connect,
FC, on a Node within the radio range of the Main Unit or by performing a Force
Connect, FC, on the Main Unit by flicking the Rocker Switch between on and off once.
When the Main Unit is active with a measurement session, the red LED flashes with 2s long
pulse and flashes OFF with 0.5s. This indicates that data is being collected and stored. This is
the normal state during operation.
MAIN UNIT ACTIVE WITH A MEASUREMENT SESSION
RED LED
2 s
0.5 s
2 s
0.5 s
2 s
0.5 s
. . .
●
○
●
○
●
○
If there is an error code registered in the System, the red LED flashes with a stream of pulses
of 0.2 seconds. This means that the unit cannot be used and possibly should be sent for repairs
to an authorized service workshop.
ERROR REGISTERED
RED LED
0.2 s
0.2 s
0.2 s
0.2 s
0.2 s
0.2 s
. . .
●
○
●
○
●
○