11. WARRANTY

P.14

All 

PerfectPrime

 products go through post-production control and are 

governed by the following warranty terms. The buyer’s right to claim about 

defects and general provisions of the current legislation do not expire.

• 

PerfectPrime 

agrees to eliminate all defects in the product, discovered 

while warranty period, that represent the defect in material or workman-

ship in full volume and at its own expense.

• 

The warranty period is 24 months and starts from the date of purchase by 

the end customer (see the original supporting document).

• 

The warranty doesn’t cover defects resulting from wear and tear or 

improper use, malfunction of the product caused by failure to observe the 

instructions of this user manual, untimely maintenance and service and 

insufficient care, the use of non-original accessories and spare parts. 

Modifications in design of the product relieve the seller from responsibili-

ty for warranty works. The warranty does not cover cosmetic damage, that 

doesn’t hinder normal operation of the product.

• 

PerfectPrime 

reserves the right to decide on replacement or repair of the 

device. 

• 

Other claims not mentioned above, are not covered by the warranty.  

• 

After holding warranty works by 

PerfectPrime 

warranty period is not 

renewed or extended.

• 

PerfectPrime 

is not liable for loss of profit or inconvenience associated 

with a defect of the device, rental cost of alternative equipment for the 

period of repair. In warranty case please return the product to retail seller 

or send it with description of defect to the following address:             
[email protected]

Содержание TM0300

Страница 1: ...Infrared Thermometer TM0300 Instruction Manual...

Страница 2: ...4 1 DISPLAY 4 2 KEYBOARD 4 3 INSTALL REPLACE BATTERIES 4 4 SWITCH ON OFF 5 Surface Temperature Mode 6 Body Temperature Mode Human head icon ON Laser icon OFF 7 EMISSIVITY 8 SWITCH ON THE DEVICE 9 OPT...

Страница 3: ...ithout the need You can dazzle them To protect your eyes close them or look aside Do not let unauthorized people enter the zone of product operation Store the product beyond reach of children and unau...

Страница 4: ...rking continuous measurement mode provide simple and convenient measurement of temperature of dangerous moving hard to reach distant objects at less than 1 second at just one touch of the trigger The...

Страница 5: ...ature accuracy Body operation temperature Body Measurement distance Smallest unit displayed 30 30mm LCD with backlight 50 C to 600 C 58 F to 1112 F 50 C to 20 C 58 F to 4 F 20 C 0 C 4 F 32 F 0 C to 60...

Страница 6: ...issivity Storage temperature Relative humidity for operation and storage Power supply Battery life Automatic shutdown Laser Dimensions Weight 12 1 0 1 sec 8 to 14 m 0 1 to 1 00 adjustable 10 to 60 14...

Страница 7: ...4 PRODUCT DESCRIPTION P 6 Display Keyboard Trigger Laser spot marking exit window Infrared sensor Battery cover 4 1 2 3 6 5 2 3 4 5 6 1...

Страница 8: ...Indication of battery charge level Measuring units or F Maximal minimal measurement value Indication of maximal minimal value Indication of activated laser spot marking Measurement result Surface Tem...

Страница 9: ...Remove the battery cover Install the battery observing correct polarity Put the battery cover back and push it until a click is heard If the symbol of low battery change level appears on the display...

Страница 10: ...switch the lower display for MAX Temp and MIN Temp 3 To turn on or off laser Press Laser key to turn ON or OFF the laser function 4 To change temperature unit Press C F key to toggle the unit of temp...

Страница 11: ...he numbers on the screen flashing Press Laser key to change to alert settings In this mode the number on the screen will be flashing and there will be AL displayed Press Min Max to increase the value...

Страница 12: ...and uncoated metal because their emissivity is less than 0 6 Adjustment of emissivity helps to take this feature into consideration and minimize inaccuracy of temperature measurement Material Emissiv...

Страница 13: ...the product to extreme temperatures If liquids get inside the product first remove the batteries then contact a service center Do not store or use the product under high humidity conditions for a lon...

Страница 14: ...le Please send the product to the following address for proper recycle Do not throw the product in municipal waste According to European directive 2002 96 C expired measuring tools and their component...

Страница 15: ...the instructions of this user manual untimely maintenance and service and insufficient care the use of non original accessories and spare parts Modifications in design of the product relieve the sell...

Страница 16: ...r products and services please send us an email cs perfectprime com For B2B or project based application please send an email sales perfectprime com FOR MORE INFORMATION ABOUT PERFECTPRIME PLEASE VISI...

Страница 17: ...Tyche Smart Limited cs perfectprime com 2nd Floor 107 Charterhouse Street EC1M 6HW London England UNITED KINGDOM 44 203 7695377 Retailer Email Address Telephone...

Отзывы: