background image

TB---PAC

TB---PHP

Base Series Programmable Thermostats

Installation Instructions

Designed and Assembled

in the USA.

US patents: US20060165149 A1, USD578026 SI, US6205041 B1

A07107

Base Series Programmable Thermostat

NOTE

: Read the entire instruction manual before starting the

installation

TABLE OF CONTENTS

PAGE

SAFETY CONSIDERATIONS

1

. . . . . . . . . . . . . . . . . . . . . . . . .

INTRODUCTION

1

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

INSTALLATION CONSIDERATIONS

1

. . . . . . . . . . . . . . . . . . .

INSTALLATION

2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Step 1 — Thermostat Location

2

. . . . . . . . . . . . . . . . . . . . . . . .

Step 2 — Install Thermostat

2

. . . . . . . . . . . . . . . . . . . . . . . . . . .

Step 3 — Set Thermostat Configuration

3

. . . . . . . . . . . . . . . . .

Step 4 — Understand Thermostat Operation

3

. . . . . . . . . . . . . .

Step 5 — Check Thermostat Operation

4

. . . . . . . . . . . . . . . . . .

WIRING DIAGRAMS

4

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

SAFETY CONSIDERATIONS

Improper installation, adjustment, alteration, service, maintenance,

or use can cause explosion, fire, electrical shock, or other

conditions which may cause death, personal injury, or property
damage. Consult a qualified installer, service agency, or your

distributor or branch for information or assistance. The qualified
installer or agency muse use factory--authorized kits or accessories

when modifying this product. Refer to the individual instructions

packaged with the kits or accessories when installing.
Follow all safety codes. Wear safety glasses, protective clothing,

and work gloves. Have a fire extinguisher available. Read these
instructions thoroughly and follow all warnings or cautions

included in literature and attached to the unit. Consult local
building codes and the current editions of the National Electrical

Code (NEC) NFPA 70.
In Canada, refer to the current editions of the Canadian Electrical

Code CSA C22.1.

Recognize safety information. This is the safety--alert symbol

.

When you see this symbol on the unit and in the instructions or
manuals, be alert to the potential for personal injury.
Understand the signal words

DANGER

,

WARNING

, and

CAUTION

. These words are used with the safety--alert symbol.

DANGER

identifies the most serious hazards which

will

result in

severe personal injury or death.

WARNING

signifies a hazard

which

could

result in personal injury or death.

CAUTION

is used

to identify unsafe practices which

may

result in minor personal

injury or product and property damage.

NOTE

is used to highlight

suggestions which

will

result in enhanced installation, reliability, or

operation.

INTRODUCTION

There are two Base Series programmable thermostat models, one
for AC applications and one for HP applications. Both are dual

powered, operating from either 24VAC or two alkaline AA

batteries. Configuration and program schedules are stored in
non--volatile memory, preserving this information during power

loss and battery removal. Features include simplified 5/2 day
programming, large backlit display, and modern styling.
The AC model provides one stage of heating and one stage of

cooling.
The HP model provides two stages of heating and one stage of

cooling.

INSTALLATION CONSIDERATIONS

AC Operation

For 24VAC operation, both the R and C wires must be connected

to the 24VAC power source. Batteries are not needed.

Battery Operation

When batteries are used, the common (C) connection is not needed,

saving a wire, and eliminating 24VAC operation. The thermostat

continues to operate in the event of a power failure. Battery life is
expected to be one year. A “low battery” reminder tells the

homeowner when it is time to replace the batteries. When
connected without the common wire, the thermostat will not

operate without batteries. Continuous back--lighting is not

available.

Both Battery and AC Operation

If both batteries and 24VAC operation are used (batteries installed

and the common wire connected), and indefinite clock operation
are provided, the battery will be used only during AC power loss,

extending battery life to nearly its shelf life.
A jumper has to be properly set for backlight operation. J2 should
be set in the “AC” position when the thermostat is operated from

24VAC. J2 should be set in the “BAT” position when the

Содержание BASE SERIES PROGRAMMABLE THERMOSTATS TB-PAC

Страница 1: ...identifies the most serious hazards which will result in severe personal injury or death WARNING signifies a hazard which could result in personal injury or death CAUTION is used to identify unsafe practices which may result in minor personal injury or product and property damage NOTE is used to highlight suggestions which will result in enhanced installation reliability or operation INTRODUCTION ...

Страница 2: ...re is disconnected record wire color and terminal marking d Discard or recycle old thermostat ENVIRONMENTAL HAZARD Failure to follow this caution may result in environmental damage Mercury is a hazardous waste and may be found in the old thermostat Federal regulations require that Mercury be disposed of properly CAUTION 3 Separate front and back plastic assembly of thermostat 4 Route thermostat wi...

Страница 3: ...a separate G signal to operate the blower when W is applied This option allows a HP thermostat to control an AC system Option 10 Reversing valve Selections C reversing valve energized in cooling This is default H reversing valve energized in heating Only appears in HP systems Option 13 Room Air Temperature Offset Selections 5_F 3_C Default is 0 The number of degrees to be added to the displayed te...

Страница 4: ...art continuous fan operation FAN ON icon will turn on 2 Press FAN button again This will stop continuous fan oper ation FAN ON icon will turn off Heating Operation 1 Press H C button until HEAT is displayed 2 Press UP button until LCD readout reads 3_F 2_C above room temperature Press UP and FAN buttons simultan eously to defeat timers Heating system should begin to op erate immediately 3 For HP t...

Страница 5: ...m Temperature The large display reads room temperature until a button is pressed 4 To Adjust the Setpoint In normal operation the large display shows room temper ature At the first press of the UP or DOWN button the large display shows the current setpoint and the SET TEMP icon is turned on Further presses of the UP or DOWN but ton adjust the setpoint upward or downward Five seconds after the last...

Страница 6: ...er your programmed comfort schedule Method 2 Temporary Override At the first press of the UP or DOWN button the current temperature setting will appear on the display Pressing the UP or DOWN button again will temporarily change the setpoint as needed At the next programmed time the programmed comfort schedule will resume CHANGING BATTERIES In some situations two AA batteries are the power source f...

Страница 7: ...d is transferable only to the extent and as stated in the Warranty Conditions and below The warranty period in years depending on the part and the claimant is as shown in the chart below Limited Warranty Years Series Item Original Owner Subsequent Owner Infinity User Interface Smart Sensor 10 or 5 10 or 5 Zoning Board 10 or 5 10 or 5 Network Interface 10 or 5 10 or 5 Remote Access 10 or 5 10 or 5 ...

Страница 8: ... AN IMPLIED WARRANTY OR CONDITION LASTS SO THE ABOVE MAY NOT APPLY TO YOU THE EXPRESS WARRANTIES MADE IN THIS WARRANTY ARE EXCLUSIVE AND MAY NOT BE ALTERED ENLARGED OR CHANGED BY ANY DISTRIBUTOR DEALER OR OTHER PERSON WHATSOEVER THIS WARRANTY DOES NOT COVER 1 Labor or other costs incurred for diagnosing repairing removing installing shipping servicing or handling of either defective parts or repla...

Отзывы: