PERFECT FRY COMPANY PFC570-HB Скачать руководство пользователя страница 5

5

REGULATIONS

Installation of your Perfect Fry PFC

 must conform to all local fire and health regulations and building 

codes. The installation use and maintenance is to be in accordance with the Standard for Ventilation 

Control and Fire Protection of Commercial Cooking Operations, NFPA 96 - 2004.

The table below describes the standards that your Perfect Fry PFC has been tested to and the 

corresponding listing marks.

STANDARD

DESCRIPTION

LISTING MARK

UL 197

UL710B

Commercial electric cooking appliances.

Commercial electric cooking appliances with recirculating systems.

UL 197 & UL 197 SB supplement also reference the following

standards which your PERFECT FRYER meets applicable parts thereof:

• 

UL 1046: Grease Filters for Exhaust Ducts.

•  UL 300: Fire Testing of Fire Extinguishing Systems for Protection 

of Restaurant Cooking Areas.

•  UL 900: Standard for Air Filter Units

•  NFPA 17A: Wet Chemical Extinguishing Systems.

•  NFPA 96: Standard for Ventilation Control and Fire Protection of 

Commercial Cooking Operations.

•  EPA 202: Determination of Condensible Particulate Emissions for 

Stationary Sources.

CSA 22.2

No. 109-M1981

Commercial Cooking Appliances forming part of Canadian Electrical 

Code, Part 2 Safety Standards for Electrical Equipment.

NSF 4

Commercial Cooking, Rethermalization, and Powered Hot Food Holding 

and Transport Equipment.

APPROVALS

Содержание PFC570-HB

Страница 1: ...mation and retain this manual for the life of the equipment Model ______________________________________ Serial ______________________________________ Date Purchased ________________________________ I...

Страница 2: ...are not attributable to a defect in materials or workmanship are not covered This warranty specifically excludes parts which wear or would be replaced under normal usage including but not limited to...

Страница 3: ...shipment Take comfort in knowing that our local Authorized Service network is committed to supply ing your service and warranty needs Each Authorized Service and Parts Provider ASAP has dedicated serv...

Страница 4: ...turn the Perfect Fry PFC for recycling when it reaches end of life SAFETY FIRST LIFTING MOVING Your Perfect Fry PFC s gross shipping weight is 100 lb 45 kg Net weight 80 lb 36 kg DEEP FRYING Cooking o...

Страница 5: ...ms UL 197 UL 197 SB supplement also reference the following standards which your PERFECT FRYER meets applicable parts thereof UL 1046 Grease Filters for Exhaust Ducts UL 300 Fire Testing of Fire Extin...

Страница 6: ...ly Air Filter Switch 3HT724 C 8 Assembly Grease Filter 3HT727 NS Switch Grease Filter Door 6HT566 9 Assembly Grease Filter Tray 6ST728 C NS Assembly Filter Drain Hose B6698901 C 10 Assembly Elec Box M...

Страница 7: ...ptacle have an electrician install the appropriate NEMA receptacle within 4 feet of the fryer See the manufacturer s label on your Perfect Fry PFC for the electrical Model No PFC570 then check off you...

Страница 8: ...23 58 42 Prepare Counter top Area Required Clearances 1 on sides 2 on rear 0 on top Unpack 1 Cut straps on shipping box 2 Remove box top and sleeve 3 Remove outer plastic wrapping and keep box along w...

Страница 9: ...ly with additional help as needed and place it in its final location EQUIPMENT SET UP AND CLOSE PROCEDURES INSTALLATION Continued Unpack 1 Air Filter Cage 2 Air Filtration Odor Filter 3 Air Filtration...

Страница 10: ...Continued Unpack BLOW OFF CAPS 12 REAR PLUG COVER HOLDER 7 Ensure that blow off caps on fire extinguisher nozzles are kept in place 8 When removing item 12 please relocate to upper holding location de...

Страница 11: ...LEASE CHECK CHANGE HEATER BOX GREASE FILTER AIR FILTER REPLACEMENT FRONT PANEL The heater box must NOT be immersed in water or any other liquid 3 Install grease filter into grease filter tray 4 Instal...

Страница 12: ...tom cooking compartment Note Indents on bottom of spill tray should fit into matching indents on bottom of cabinet 8 Set heater module onto oil vat Note grooves on bottom of heater module should fit o...

Страница 13: ...and inside edge of spill tray Note If drip tray does not fit press heater module in further to complete connection 12 Install basket lift a Hold basket tray vertical b Install rod into pivot hole left...

Страница 14: ...trate Cleaner solution APSC Rinse them under hot fresh water then sanitize in sanitizer solution for 1 minute Allow to air dry 3 Open the fryer door and clean the inside of the fryer area by spraying...

Страница 15: ...n water and allow to air dry 6 Remove the air filter cartridge and set aside CAUTION Do not wash the air filter cartridges 7 Remove the grease baffle tray from the cabinet Remove the grease baffle fro...

Страница 16: ...r solution for 1 minute Allow to air dry NOTE Place the Yellow Protective Cover that comes with the fryer unit back on top of the female connector at the interior back of the unit behind the vat befor...

Страница 17: ...ent 3 Remove old used air filter cartridges from air filter cage 4 Wipe air filter cage clean 5 Fit air filter cage over new air filter cartridges as shown and write date on cartridge Arrows up 6 Inst...

Страница 18: ...by 10 second increments Number Keys 0 to 9 Preset Key Choose any of the default presets On Off Key To turn ON To turn OFF To put in STANDBY Preset Mode Shows which preset mode the Perfect Fry PFC is...

Страница 19: ...ached unit is READY to start cooking READY PRESET 359 F Preset Times Cooking Time Names Factory Defaults Preset Name Time Preset Name Time Preset Name Time 1 HASHBROWNS 3 00 4 AVAILABLE 0 00 7 AVAILAB...

Страница 20: ...Wait for Beep 8 Open door 9 Remove Basket 10 Follow steps 2 through 6 to cook another order this way 7 COOKING cycle is complete 8 Basket raised out of oil 9 Basket drains 10 Fryer beeps to inform you...

Страница 21: ...D CONTROL Operation Instructions continued Open Door Paused Cooking Safety and Health regulations require doors and panels to be closed during cooking YOU DO THIS 1 Open door during cook cycle Perfect...

Страница 22: ...stop 9 LCD goes blank 10 Your Perfect Fry PFC is off DO NOT UNPLUG FRYER Fans must remain ON during COOLDOWN mode Drain Mode Note Oil in Perfect Fry PFC must be cooler than 139 F or drain mode will no...

Страница 23: ...UNTERS MORE START TO SELECT Preset Key Use in combination with START CANCEL to access background menu Left Arrow Key Moves menu selection up Toggles character selection up in making preset names Numbe...

Страница 24: ...when a basket of product is placed into the fryer CTSTM increases cooking time to accommodate for differences in product moisture content basket load size and initial temperature A proper CTSTM setti...

Страница 25: ...a key is pressed Choose between 0 and 9 Default is 4 Units Temperature of oil in the vat Choose between C Celsius and F Fahrenheit Drain Time Time a basket of cooked food sits out of the oil before y...

Страница 26: ...BROWNS 2 AVAILABLE 3 AVAILABLE 4 AVAILABLE 5 AVAILABLE 6 AVAILABLE 7 AVAILABLE 8 AVAILABLE 9 AVAILABLE Preset properties that can be changed TIME Cook Cycle Time TEMP Cook Cycle Temperature CTS Cook T...

Страница 27: ...onnel FANS Use the arrow keys to turn fans on and off note oil temperature must be below 122 F 50 C Monitor rpm and current values of each fan INTERLOCKS To view interlocks and if they re open or clos...

Страница 28: ...ms can be customized by following this basic proce dure some use the arrow keys Option Changes Adding Presets 1 From main menu scroll down to PRESETS using key 2 Press SEE THIS LCD DO THIS GET THIS LC...

Страница 29: ...heck to see that front panel is closed securely with two black latches SEE THIS LCD CAUSED BY DO THIS GET THIS LCD HEATING PRESET 84 F SYSTEM ERROR PLEASE CHECK FILTER PLACEMENT Air filter cartridge i...

Страница 30: ...le and connector is made at inside back of fryer compartment Clean the male and female terminals on connector with rubbing alcohol and cotton swab HEATING PRESET 84 F SYSTEM ERROR PLEASE CHECK SECONDA...

Страница 31: ...heater module Replace electronics box module Baskets will not lower into or rise out of cooking oil Basket lift not working Motor not working Make sure that the basket lift is installed properly Chec...

Страница 32: ...ieved by system operation If the pressure in the cylinder drops below 92 psi 6 3 bar the pressure switch opens deactivating the power relay causing the appliance to de energize INSPECTION MAINTENANCE...

Страница 33: ...he affected parts must be replaced or repaired 4 The maintenance report with recommendations if any shall be filed with the owner or with the designated party responsible for the PFS 5 The PFS must ha...

Страница 34: ...34 THIS PAGE WAS LEFT BLANK INTENTIONALLY...

Страница 35: ...r Female Motor Basket PFC Switch Air Filter Switch Airflow Switch Grease Filter L1 L2 G H2 H1 OT NC NC NC NO NC NC C NO NC 1 2 3 4 5 6 9 10 11 12 13 14 15 16 1 2 3 4 5 6 7 8 10 9 8 7 6 5 4 3 2 1 20 19...

Страница 36: ...d NH 03302 0501 Physical Address 553 Route 3A Bow NH 03304 Tel 603 225 6684 Fax 603 225 8472 General Information profits perfectfry com Customer Support service perfectfry com Web www perfectfry com 2...

Отзывы: