background image

IMPORTANT SAFETY INSTRUCTIONS

Be sure the electrical service is adequate for the model you have
chosen. This information can be found on the serial plate, which
is  located on the side of the cabinet and behind the grill.
Be sure the air conditioner is properly grounded. To minimize 
shock and fire hazards, proper grounding is important. The power 
cord is equipped with a three-prong grounding plug for protection 
against shock hazards.
Your air conditioner must be used in a properly grounded wall 
receptacle. If the wall receptacle you intend to use is not adequately 
grounded or protected by a time delay fuse or circuit breaker, 
have a qualified electrician install the proper receptacle. 
Ensure the receptacle is accessible after the unit installation.
Do not run air conditioner without side protective cover in place. 
This could result in mechanical damage within the air conditioner.

Do not use an extension cord or an adapter plug.

WARNING

For your safety

Do not store or use gasoline or other flammable vapors and liquids in
 the vicinity  of this or any other appliance.
Avoid fire hazard or electric shock. Do not use an extension cord or an 
adaptor plug. Do not remove any prong from the power cord.

WARNING

Electrical Information

NOTE 

The power supply cord with 

this air conditioner contains a current 
detection device designed to reduce 
the risk of fire.
Please refer to the section Operation
of Current Device for details.
In the event that the power supply 
cord is damaged, it must be replaced
by an authorized repairman.

,

,

Do not, under any
circumstances, cut,
remove, or bypass
the grounding prong.

Power supply cord
with 3-prong grounding plug
and current detection device

Operation of Current Device

The power supply cord contains a current device that senses damage to the power cord. To test your power 
supply cord do the following:
                                                            1. Plug in the Air Conditioner.
                                                            2. The power supply cord will have TWO buttons on the plug head. 
                                                                Press the TEST button, you will notice a  click as the RESET 
                                                                button pops out.
                                                            3. Press the RESET button, again you will notice a click as the button
                                                                engages.
                                                            4. The power supply cord is now supplying electricity to the unit. 
                                                                (On some products this it also indicated by a light on the plug head.)

NOTES:

    Do not use this device to turn the unit on or off.
    Always make sure the RESET button is pushed in for correct operation.
    The power supply must be replaced if it fails to reset when either the TEST button is pushed, or it cannot be 
    reset. A new one can be obtained from the product manufacturer.
    If power supply cord is damaged, it cannot be repaired. It MUST be replaced by an authorized repairman.

4

(Applicable )

to the unit adopts current detection device only

Содержание 12.000 BTU

Страница 1: ......

Страница 2: ...rm persons without supervision Young children should be supervised to ensure that they do not play with the air conditioner If the power cord is to be replaced replacement work shall be performed by a...

Страница 3: ...ire and burns It may cause electric shock or fire due to heat generation It may cause electric shock It may cause failure of machine or electric shock It may cause fire and electric shock It may cause...

Страница 4: ...ets plants and art objects It may cause deterioration of quality etc It may cause failure of product or fire Do not use for special purposes Turn off the main power switch when not using the unit for...

Страница 5: ...he power supply cord with this air conditioner contains a current detection device designed to reduce the risk of fire Please refer to the section Operation of Current Device for details In the event...

Страница 6: ...as shown below and all its functions then follow the symbol for the functions you desire The unit can be controlled by the unit control alone or with the remote control Vibration Unit may vibrate and...

Страница 7: ...f you want the display to read the actual room temperature see To Operate on Fan Only section on page 7 NOTE TO ADJUST FAN SPEEDS Press to select appropriate fan speed DO THIS NOTE Sleep Check Filter...

Страница 8: ...de This function is available on COOL mode The fan will continue to run for 3 minutes after the compressor shuts off The fan then cycles on for 2 minutes at 10 minute intervals until the room temperat...

Страница 9: ...ime remaining until start The selected time will register for 5 seconds and the system will automatically revert back to display the previous temperature setting or room temperature when the unit is o...

Страница 10: ...d Left or Right throughout the room as needed To adjust the air directional louvers side to side use the center handles as you move it side to side Air Direction 4 way INSTALLATION INSTRUCTIONS Do Thi...

Страница 11: ...ditioner from wall sleeve and prepare wall sleeve as follows Clean interior do not disturb seals Wall sleeve must be securely fastened in wall before installing air conditioner Drive more nails or scr...

Страница 12: ...re is an existing rear grill the louvers will have to be bent as per the instructions at the beginning of each section If this proves too difficult to accomplish EITHER 1 Remove the existing grill 2 P...

Страница 13: ...2 4 x3 x1 centering support blocks one on each side wall Place in center of side wall with the tapered end facing the opening 6 Gently slide unit into sleeve 7 Before sliding all the way back remove...

Страница 14: ...of the rear grille as shown 8 Gently slide unit into sleeve 9 Before sliding all the way back remove 2nd screw from front on left side of unit 10 Remove the plastic washer from the screw 11 Screw and...

Страница 15: ...e top of the sleeve Remove the backing paper and press into position 6 Attach 2 1 x3 8 x14 seals to the left and right sides of the sleeve 7 Cut 2 1 x3 8 x25 long seal to 14 long and attach it to the...

Страница 16: ...sleeve 6 Cut 2 1 x3 8 x25 long seal to 14 long and attach it to the vertical sections of the rear grill as shown 7 Center unit and gently slide unit into sleeve 8 Before sliding all the way back remo...

Страница 17: ...o position 5 Attach 2 1 x3 8 x14 seals to the left and right sides of the sleeve 6 Cut 2 1 x3 8 x25 long seal to 14 long and attach it to the vertical sections of the rear grill as shown 7 Center unit...

Страница 18: ...1 x3 8 x25 long seal to 14 long and attach it to the vertical sections of the rear grill as shown 7 Center unit and gently slide unit into sleeve 8 Before sliding all the way back remove 2nd screw fro...

Страница 19: ...overlapping the seal above 11 Install the divider into the slots of the foam blocks You may need to trim the length to size 12 Repeat steps 9 11 for the other vertical shown portion of the grill as sh...

Страница 20: ...vertically 7 from the left and right sides of the sleeve 5 Center unit and gently slide unit into sleeve 6 Before sliding all the way back remove 2nd screw from front on left side of unit 7 Remove the...

Страница 21: ...tach 2 1 x1 x14 seals along the sides of the sleeve again making sure all seals are flush 13 Cut the 1 x1 x25 seal to fit the top of the sleeve The pieces must be fitted flush to the edge of the divid...

Страница 22: ...grill over the rear of the unit making sure that a The double set of screw holes are at the bottom b The fins of the grill are pointed away from the unit 3 Align the top of the grill with the top of t...

Страница 23: ...en the wall sleeve and the unit A flat bladed screwdriver or putty knife is recommended 1 2 2 Assemble the trim frame by inserting top and bottom pieces into side pieces and snapping into place 3 Pull...

Страница 24: ...air filter Never attempt to operate the unit without the air filter Cabinet Cleaning Be sure to unplug the air conditioner to prevent shock or fire hazard The cabinet and front may be dusted with an...

Страница 25: ...F Turn Control ON and set to desired setting O O O O Air conditioner cooling but room is too warm ice forming on cooling coil behind decorative front Outdoor temperature below 62 F 17 C To defrost the...

Страница 26: ...20 feet 180 radius of the front of the unit Remote control signal obstructed Remove obstruction Room too cold Set temperature too low Increase set temperature 25 The design and specifications are subj...

Страница 27: ......