33
Electric diagram for switching valve of the reserve
boiler, where: 1
–
regulator ecoMAXX, 2
–
reserve
boiler, 3,4
–
relay RM 84-2012-35-1012 RELPOL
and base GZT80 RELPOL, 5
–
servo of switching
valve
11.12
Connection of alarm signaling
The regulator may announce an alarm
condition by activating external device (e.g.
bell or GSM device to send SMS). Alarm
signaling and reserve boiler control use the
same terminals, therefore, setting of the H
output for alarm signaling deactivates the
function of reserve boiler control. Connect
alarm annunciator through U3 module.
Connection of an external alarm annunciator 1 -
ecoMAXX regulator - module A, 2
–
external alarm
annunciator, 3
–
relay RM 84-2012-35-1012
RELPOL and base GZT80 RELPOL,
For proper operation, set proper value of the
parameter:
Active alarm signal code
in:
MENU
Service Settings
Boiler
Settings
Alarms
Active alarm
signal code
When "31" has been set - in case of any
alarm occurred, voltage is applied at contact
43-44. Setting this parameter at "0" causes
the regulator does not apply voltage upon
occurrence of any alarm. Contact 43-44 may
be so set up that the voltage will be applied
at it upon occurrence of one or few alarms.
The values of this parameter to be set for
respective alarms are given in the table
below:
B
o
ile
r
o
ve
rh
eat
in
g
Fl
ash
b
ack
CH
b
o
ile
r
te
mp
erat
u
re
sen
so
r
d
amage
Fee
d
er
te
mp
era
tu
re
sen
so
r
d
amage
No
f
u
el
B
o
ile
r
o
ve
rh
eat
ed
,
S
TB
co
n
n
ect
o
rs
d
isco
n
n
ect
ed
re
lay
f
ai
lu
re
i
n
t
h
e
fe
ed
er
p
at
h
AL 1 AL 2
AL 3
AL 4 AL 5 AL6
AL7
1
2
4
8
16
32
64
Example: when this parameter is set at
”8”,
voltage will be applied at the contact only
upon occurrence of an AL4 alarm. In case of
”1” setting
only alarm AL1 will be announced.
In case the contact should signal few alarms
(e.g. AL2 and AL4 alarms) - sum-up the
Содержание KSM 17
Страница 1: ...Operation and maintenance manual for the KSM series boilers with feeders...
Страница 26: ......
Страница 31: ...REGULATOR INSTRUCTION MANUAL ecoMAX 910R1...
Страница 41: ...USER MANUAL OF CONTROLLER INSTALLATION AND SERVICE SETTINGS ecoMAX 910R1...
Страница 47: ...23...
Страница 71: ...47...
Страница 74: ......
Страница 75: ...3 This sign indicates relation to safety issues This sign indicates relations to module functional features...
Страница 102: ......
Страница 103: ......