Assembly & Operation Manual
Pass elements for “PASS A”, “PASS B”, “Ready”, “Detector” - relay contacts (Fig. 11) with the
following signal characteristics:
maximum commutation DC voltage
....................................................................................... 42V
maximum commutation current ............................................................................................ 0.25A
closed contact resistance ....................................................................................... max 0.15
Ohm
Pass elements for
«Alarm» and «Battery» – relay contacts (Fig. 11) with the following characteristics:
maximum commutation DC voltage ........................................................................................ 30V
maximum commutation AC voltage
........................................................................................ 42V
maximum commutation AC/DC current
....................................................................................... 3
closed contact resistance ....................................................................................... max 0.15
Ohm
5.4.2 Intrusion detector and siren
Caution!
Installation of the intrusion detector is made in accordance with the passage area layout and
climatic resistance of the detector. No intrusion detector installation inside the turnstile post
is possible.
The intrusion detector is connected to the
X4
connector block contacts, and the siren is connected
to the
X1
connector block on the interface board (10) according to the connection layout (Fig. 7
and 17). There should be normally closed contacts on the intrusion detector. In case the intrusion
detector is not connected, it is necessary to set a wire jumper between the contacts
DKZP1
and
GND
of the
X4
connector block. The jumper is installed upon delivery.
The siren is connected to the
Alarm 1, Alarm 2
and
GND
contacts and +12V of the
XT1.H
connector
block. The parameters of the alarm relay output signals “Alarm” are indicated in Sect. 5.4.1
.
If the turnstile is locked (the command “
Always Locked
” or “
Both passage directions are locked
” is
DKZP1
input is activated and a signal comes from the intrusion
detector, the “Alarm” output is activated. The "Alarm" output is disabled 5 sec. after activation or by
executing of any received command.
The signal from the intrusion detector is ignored for the period
of authorized unblocking of the turnstile in either or both directions.
Note:
The control signal from the intrusion detector does not activate the
ALARM
output if the
turnstile turning mechanism is unlocked in one of the directions or was blocked less than
3 sec. ago.
A signal about the intrusion detector current state is always transmitted to the
DETECT
contacts
(relay "Detector") and
COM
of the
X5
connector block on the interface board (Fig. 7).
The parameters of the “Detector” relay output signals are indicated in Sect. 5.4.1.
5.4.3 Remote indicators
Remote indicators for corresponding passage directions are connected to
X3 (LIGHT)
connector
blocks -
NO1, C1, NC1, NO2, C2, NC2.
The relay “Light A” (“Light B”) is activated (voltage is
supplied to its winding) when the green arrow corresponding to this direction of passage is lit on
the LED indication unit, and normalized (voltage is not supplied to its winding) when it is not lit. The
fact of “Light A” and “Light B” relays operation can be determined by the state of the indicators that
are installed near the indicated relays (Fig. 7) (this indication works when the
XP2 (+12LED)
jumper
is installed).
Pass elements for “Light A” and “Light B” - relay transfer contacts (Fig. 12) with the following signal
characteristics:
maximum commutation DC voltage
....................................................................................... 30V
maximum commutation AC voltage......................................................................................... 42V
maximum commutation AC/DC current..................................................................................... 3A
closed contact resistance ....................................................................................... max 0.15
Ohm
16