TTR-10A electromechanical tripod turnstile
XP1
– programming socket (not used during operation);
XP2
(
USB
UPD
) – the jumper of the board software update via USB. If the jumper is fixed -
the update mode is
ON
, if removed – the update mode is
OFF
;
SA1
(
CONTROL
) – a set of DIP switches for setting the electric drive, must be in the
OFF
position (not used during operation);
PWR
– green LED indicator for interface board power supply.
Figure 6. Control board
The interface board (10) processes the incoming commands (monitors the status of
contacts L, ST,
R
and
FA (Fire Alarm),
reads information from the intrusion detector (
DKZP1
contact) and
generates commands to the control board (9), as well as signals for external devices, for RC-panel
indications (
Led A, Led ST
and
Led B
), for the barrier arms rotation in the corresponding direction
(
Pass A
and
Pass B),
for the alarm output A1 – A2 (Alarm) and relays the signal about the current
status of the intrusion detector (
DETECT
).
The following devices are connected to the interface board: RC-panel / WRC / ACS controller,
emergency unblocking
Fire Alarm
device, remote display units and other optional equipment.
Wired connection is made in accordance with the connection layout (Fig. 17).
The general view of the interface board (10) (Fig. 7).
Figure 7. Interface board
Interface board elements:
X1
(
ACS
) – additional equipment power supply connector blocks (
X1.1
), siren connection
(
X1.2
) and ACS controller inputs for PASS signals (
X1.3
);
X2
(
RC
) – connector blocks for connecting the RC-panel, WRC or ACS controller (
X2.1
), as
well as emergency unblocking
Fire Alarm
device (
X2.2
);
X3
(
Light
) – connector blocks for connecting remote indicators (“open” / “closed”,
X3.1
– for
direction
A
,
X3.2
– for direction
B
);
9