1. APPLICATION
1
2
3
4
1
LB-85.4
is a normally-opened electromechanical mortise door lock
(hereinafter – the lock), designed to be used as an operating device as a part
of access control system (hereinafter – ACS) to control light and medium
office doors.
Lock features:
• the lock has installed in wooden and non-metallic doors 38-50 mm thick;
• the lock has a unique construction, allowing to connect lock control cable
through the strike plate in the door frame, not through the door leaf, which
makes installation easier;
• when connecting to "PERCo" ACS controllers, operation of the lock can be
maintained without using a door sensor (reed switch), the contact group of
the lock is used instead;
• automatic orientation of the contact group relatively of the locking bolt,
implemented through the use of neodymium magnets, can significantly
increase the tolerances during installation and the reliability of the lock;
• the lock design allows you to use almost all types of lever handles that are
on the market;
• the lock is designed for use with standard lock cylinders;
• a universal lock construction enables its installation on both right-handed
and left-handed doors;
• in the absence of supply voltage, the lock is not locked;
• with voltage applied the lock closes automatically at shutting the door;
• with voltage applied the lock can be open with the key;
• forend plate, strike plate and locking bolt made of stainless steel; details
and lock body have corrosion-resistant coating;
• the lock is resistant to self-opening (for instance, as result of a hard kick on
the door);
• the design of the lock does not require preventive maintenance and
lubrication from the customer for the entire period of operation;
• the lock has low power consumption (max 2 W).
The lock with regard to resistance to environmental exposure complies with
GOST 15150-69, category NF4 (operation in premises with climate control).
Operation of the lock is allowed at ambient air temperature from +1°C to
+40°C and at relative air humidity of 75% at+15°C.
The universal construction provides use of standard pin-type lock cylinders, standard
EuroDIN (V DIN 18254), e.g. type 8809, 8209 produced by company ISEO (Italy),
or
lock cylinders of D series by Wilco Supply (type
254 – 274 – 294, 453, 454, 554) .
2
The lock cylinder with a set of keys, door levers with fixing elements, reed switch,
control and reed switch cables are not included in the delivery set.
A2
IN
NO
C
NC
+12V
VD1
Terminal block
Lock
magnet
S1
A1
A3
A4
Contact 1
Contact 2
1
2
Contact 1
Contact 2
1
2
ACS controller
IN
GND
OUT
+U
GND
+12V
+U
GND
The lock has a marking in the form of label located on its housing. Label
containts product name, its serial number, the manufacture date and its main
technical specifications.The product is packed in an carton box, protecting it
from being damaged during transportation and storage.
Box dimensions (L× W× H) ....................................................... 22×12×4 cm
Gross weight .............................................................................. max. 0.9 kg
Lock storage is allowed indoors at ambient air temperature from -50°C to
+50°C and at relative air humidity of 75% at+15°C. Storage time in closed
package is 12 months.
During storage and transportation carrying cases containing boxes with locks
can be stacked no more than 2 layers high.
The lock in the original package can be delivered by means of land (railway
and road), sea and air transport. It is allowed to stack the boxes while in
transit.
2.
TECHNICAL SPECIFICATIONS
Attention
!
Due to continuous improvement of products the Manufacturer reserves
the right to modify, without notice, the product design not aggravating its
technical specifications.
DC voltage ......................................................................................... 11 - 13V
Operational current ..................................................................... 0.08 - 0.12A
Power consumption .......................................................................... max. 2W
Type (fail-safe performance) .............................................. normally-opened
Bolt throw ......................................................................... not less than 15 mm
Centre-to-centre spacing .................................................................... 85 mm
Backset (dornmass)
............................................................................. 45 mm
The size of the square-hole for the lever rod ........................................... 8 mm
Dimensions ............................................................................ 94×22×187 mm
Weight ............................................................................ not more than 0.5 kg
Lock type ............................................................................................ cylinder
Resistance to opening
................................................................ І (EN 12209)
Electric shock protection class ................................................ III (IEC 61140)
MTBF
............................................................. 200 000 number of operations
Average lifetime................................................................................... 8 years
Design and composition of the lock are shown in Fig. 1
1
Attention!
3. STANDARD DELIVERY SET
Check the delivery set upon product receipt.
Lock ............................................................................................................ 1
Strike plate ................................................................................................. 1
Terminal block ............................................................................................ 1
Lock cylinder fastening screw
M5×50 DIN965 .
........................................... 1
Screw 3×6 DIN965
...................................................................................... 2
Screw 3.9×25 DIN7982 ............................................................................... 4
Mounting stud ............................................................................................... 5
Certificate and operation manual ................................................................. 1
Installation template
.................................................................................. 1
Package box ................................................................................................ 1
2
Fig.1. LB-85.4 electromechanical lock design
Fig. 3. LB-85.4 electromechanical lock layout
1- Lever
3
; 2 - Key
3
; 3 - Escutcheon plate fastening screw
3
;
4 - Escutcheon plate
3
; 5 - Lever rod
3
;
6 - Lock cylinder
3
; 7 - Lock; 8 - Screw 3.9×25;
9 - Strike plate; 10 - Terminal block; 11 - Terminal cables;
12 - Locking mechanism lever; 13 - Locking bolt; 14 - Forend plate;
15 - Lock cylinder fastening screw M5×50; 16 - Mounting studs
1
2
A1
12V; 0.5А; 6W
A2
A3
А4
S1
15–18 V (BZW06-15B, P6KE16CA
VD1
Fig. 2. Electromechanical lock installation layout
Position
Unit
Note
Control cable of the ACS controller
Reed switch cable
Power supply unit
Lock controller
Terminal block
Reed switch
Suppressor
Lock
3
Not included in the delivery set
WARRANTY CARD
WARRANTY REPAIR COUPON
Cutting line
Cutting line
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
A
A
B
B
B-B
A-A
C
C
C-C
Ø3.5×30
2 holes
3
25
85
113
130
2
35°
31
L 2
±1
27
±3
3
45
2
2
R3
36
4
12
13
R6
27
87
42
23
85
21
2 holes
Ø7
Ø20
2 holes
Ø3.5×30
147
22
18
165
R11
L=38...50
L- door thickness
38
Ø7
L 2
±1
+2,7
–2
Ø12±4
R9