5
6
7
LB-85.4
www.perco.com
5. MAINTENANCE
6. PERCo WARRANTY
Electromechanical
Mortise Door Lock
Certificate and Operation Manual
РОСС. RU.СП26.Н03587
ТУ 4981-049-88226999-2014
PERCo
Polytechnicheskaya str. 4, block 2
194021, Saint-Petersburg, Russia
Tel: +7 812 247 04 64
e-mail: [email protected]
www.perco.com
PERCo (the Manufacturer) warrants that the
LB-85.4
electromechanical
mortise door lock (the Product) complies with applicable statutory safety
requirements, electromagnetic compatibility provided that the instructions on
storage, installation and operation, given in the Assembly & Operation
Manual are observed.
The warranty period is 5 (five) years commencing from the date of sale.
Should there be no date of sale on the warranty card, the warranty period
shall commence from the date of manufacture.
Within the warranty period the Product is repaired free of charge at the
Manufacturer’s site.
The Warranty does not cover Products with external mechanical damages ore
disassembled by the Customer.
Upon lock purshase request the date of sale stamp in the warranty certificate
and check the completeness of the delivery set as per the Manual.
In case any questions arise during the Product assembly or operations,
PERCo Company is always ready to give you necessary technical support.
Attention
!
Attention!
In order to provide stable lock operation, it is necessary to ensure
the accuracy of the installation of the strike plate with the terminal
block relative to the locking bolt ± 3 mm vertically and ± 1 mm
horizontally (see Fig. 2). The lock operates normally if the spacing
between the forend plate and the strike plate is 1 ... 5.7 mm
(recommended clearance of 3 mm).
2. Make the hole marking for lock cylinder (6), lever rod (5) and, if needed,
of a location slot for lock forend plate (14) in the door leaf in the place of lock
installation using the installation template from the delivery set. Template
marking corresponds to the one in Fig. 2.
3. Carve out holes and choose the location slot for lock forend plate in
accordance with the marking.
4.Install the lock (7) in the locating pocket of the door and fasten it with two
screws 3.9×25 from the delivery set.
5. Mount the lock cylinder inside the lock and fix it with the screw supplied
through the hole on the lock forend plate (this screw included in delivery
set).
6. Adjust the door levers (1) with escutcheon plates (4) in accordance with
manufacturer recommendations. If necessary for fastening overlays, use
the mounting racks (16) supplied. After the installation levers are to turn
easily.
7. Fix the strike plate (9) on the terminal block housing (10) with two screws
3×6 from the delivery set.
8. Mark out and carve into the door jamb installation groove for the strike
plate with the terminal block (in accordance with Fig. 2). Use the installation
template from the delivery set.
9. Lay the control cable from the ACS to the terminal block installation place
inside the door frame. The cable laying method is determined by lock
installer and the Customer.
10. Connect the control cable to the wires of the terminal block by soldering
or use standard crimp lugs (terminals).
If the lock is operated as a part of access control system (ACS) it is
recommended to install voltage regulator diode BZW06-15B or
P6KE16CA, or another model with equal parameters on contact clips
(Fig. 3). The voltage regulator diode is used for maintaining the device
which sends the control signal.
13. If necessary, install and connect the reed switch. Installing the reed
switch ensure firm contact closure at closing the door. In the PERCo ACS
the role of the door sensor can be performed by the terminal block of the
lock itself, in this case, the installation of the reed switch is not needed
14. Connect the lock and reed switch to ACS controller according to the
scheme shown in Fig. 3.
15. Check the lock operation:
• At the opened door push in the locking mechanism lever (4) inside the
lock housing. The locking bolt will move out of the lock housing (3).
Holding the locking mechanism lever in a pressed position, turn the lever
hendle against stop. The locking bolt will return into the initial position
inside the lock housing. Keeping the locking mechanism lever in a
pressed position, leave the lock lever. The locking bolt will move out of the
lock housing. Leave the locking mechanism lever. The locking bolt will
return into the initial position inside the lock body
.
• Close the door. Apply 12V voltage to the terminal block contacts, the lock
will be closed automatically.
• Insert the key (14) inside the lock cylinder and turn it against stop to
check the mechanical unlocking. Open the door by pressing the lever
handle.
• Check several times.
If necessary, disassembling of the lock should be made in the reverse order.
11.
Mount the strike plate with the terminal block in the door frame providing
2-3 mm spacing between the strike plate and the forend when the door is
closed. The channel of the strike plate must lay symmetrical to bolt’s cross
section.
12. Mount the strike plate on the door frame with two screws 3.9×25 from
the delivery set.
4.
ASSEMBLY AND INSTALLATION
Attention
!
The locking mechanism lever should not get into the channel of the
strike plate! Otherwise, at closing the door, it can get locked with the
moving lever and then it will be impossible to open the door without
damaging the lock.
Warning!
• Do not use the lock at power supply voltage other than specified in its
technical specification.
• Do not use the lock in operation conditions other than specified in the
following Manual.
• Do not use the lock in hostile environment with atmospheric content of
acids, bases, oils, etc.
The lock is a normally-opened device, wich means that de-energized lock is
unblocked.
When you open the door from the body of the lock is automatically slided out
the locking mechanism lever. When the door is closing, the locking
mechanism lever is recessed into the lock body, and the locking bolt
automatically moves out, and the door is locking.
The lock is locked by applying and holding a voltage of +12 V on the terminal
block contacts of the lock (potential operation mode of the ACS controller).
When the lock is locked, the possibility of rotating the lever handle is blocked.
To unlock the lock use one of the following ways:
• turn the key in the mechanism of secrecy all the way and hold in this
position until the door is opened;
• remove v12V to the terminal block contacts of the lock.
After unlocking the lock, the door is opened by turning the lever handle
(approximately 20º). When you turn the lever handle, the locking bolt slides
inside the housing and you can open the door. The opening of the door is
monitored by the state of the door sensor (reed switch) or by the state of the
terminal block contacts (open circuit of the lock).
Type and length of control cable used:
- twin cable with 0.75 mm cross-section (two-color HO3VV-F, HO5VV-F
2×0.75 ) - up to 30 meters long.
Install the lock in the following order (
reference numbers are given in
accordance with Figure
1):
1. Upon delivery, the locking mechanism lever is oriented for installation on
the left door. in order to install the lock on the right door needs to change its
position (see Fig. 4). For this:
• remove the forend plate by unscrewing the three fixing screws;
• remove the locking mechanism lever with the axle;
• turn the lever 180 ° and lower its axis;
• place the lever into place with the axle in the opposite slot;
• install the forend plate and secure it with screws
Fig. 4. Locking mechanism lever position on the left and right doors
Left door
Lever axle
Locking
mechanism lever
Threaded holes for
fastening the forend plate
Right door