VIM3*-IO-* Vibration Sensors

Process Data Structure

 2

0

2

2

-1

1

17

7.1

Parameterizing a Switching Signal (SSCx)

Two independent switching signals (SSC) can be parameterized for each measured variable. 
The principle for parameterization is the same for each measured variable (SSC).

The figure below illustrates the relationships:

Figure 7.2

For example, the SCC1.1 switching signal can be used to monitor the vibration velocity "Veloc-
ity RMS." Two independent measured value limits (SP1 and SP2) can be set for monitoring a 
measurement range. This mode can also be used to switch between monitoring a measure-
ment range and monitoring an individual point. You can use "Off Delay" to set a delay time for 
how long the measured value limit can be minimally exceeded before the switching signal 
responds. This is done to prevent the SSCx switching signal from switching back and forth.

This concept is implemented for each SSCx. The appropriate parameters are available and can 
be set independently of each other.

Process data

SSC1.1

MDC3- Acceleration Peak 

MDC4 - Temperature 

MDC2- Acceleration  RMS 

MDC1 - Velocity RMS 

Maintenance request

SSC1.2

Parameter for setting SSC

vRMS SP1
(0x40.1)

vRMS Logic
(0x41.1)

vRMS SP2
(0x40.2)

vRMS Mode
(0x41.2)

vRMS Off Delay
(0x54)

Process data

Same as in Device Status

Parameter for setting SSC

vRMS SP1
(0x44.1)

vRMS Logic
(0x45.1)

vRMS SP2
(0x44.2)

vRMS Mode
(0x45.2)

vRMS Off Delay
(0x56)

...

SSC2.1

SSC2.2

SSC3.1

SSC3.2

...

SSC3.1

SSC3.2

Maintenance Status Diag

Содержание VIM3 IO Series

Страница 1: ...VIM3 IO Vibration Sensors Manual...

Страница 2: ...sion as well as the supplementary clause Expanded reservation of proprietorship Worldwide Pepperl Fuchs Group Lilienthalstr 200 68307 Mannheim Germany Phone 49 621 776 0 E mail info de pepperl fuchs c...

Страница 3: ...ies 10 3 Installation 11 3 1 Instructions for Mechanical and Electrical Installation 11 3 2 Mounting 12 3 3 Electrical Connection 12 4 Cybersecurity and Decommissioning Information 13 5 Commissioning...

Страница 4: ...ctional safety manual Additional documents 1 2 Target Group Personnel Responsibility for planning assembly commissioning operation maintenance and dismount ing lies with the plant operator Only approp...

Страница 5: ...Link network and should be used only in this way Typical applications are monitoring fans ventilators electric motors pumps centrifuges sepa rators generators turbines and similar oscillating mechanic...

Страница 6: ...ous for the user to make changes and or repairs Additionally doing so voids the warranty and excludes the manufacturer from any liability In the event of any serious errors stop using the device Secur...

Страница 7: ...wing them to perform predictive servicing The technology offers particular benefits during service activities troubleshooting servicing and device exchange during commissioning cloning identification...

Страница 8: ...oring 2 2 1 Vibration Velocity Operating Range The operating range of the vibration velocity is not constant over the entire measuring range It always depends on the current frequency at which the vib...

Страница 9: ...locity because the frequency is too high The sensor outputs the vibration velocity value that can only just be detected Example for a version with a measuring range of 128 mm s Assumption Application...

Страница 10: ...s depicted below Frequency Response 10 Hz to 1000 Hz The cut off frequencies are 10 Hz and 1000 Hz with 3 dB damping Figure 2 2 Frequency Response 1 Hz to 1000 Hz The frequency response was recorded u...

Страница 11: ...IM3 vibration sensor Accessories Use Cordset for plug versions Electrical installation for plug versions EMC adapter For insulating the sensor from the mounting point to protect against sources of EMC...

Страница 12: ...nificant risk of personal injury and property damage Warning Protect cables against interference and damage Protect the connection cable and any extension cables from electrical interference and mecha...

Страница 13: ...ng surface correctly to obtain accurate data Avoid mounting the vibration sensor on auxiliary structures If it is absolutely necessary to use auxiliary structures make sure these are designed to be as...

Страница 14: ...a point to point connection The product features a proprietary Pepperl Fuchs service interface that uses the existing con nection lines This interface is used exclusively for initially storing and upd...

Страница 15: ...sponding port on the IO Link master to which the vibration sensor is connected Once communication has been successfully established parameterize the vibration sensor with the higher level application...

Страница 16: ...on its installation and use can be found online at www pepperl fuchs com If the IO Link Offline Parameterization Tool software package is used there is active internet access and the device is connec...

Страница 17: ...ure The figure below illustrates the process data structure Figure 7 1 Two independent adjustable switching signals SSC are transmitted for each measured vari able In addition adjustable thresholds an...

Страница 18: ...ividual point You can use Off Delay to set a delay time for how long the measured value limit can be minimally exceeded before the switching signal responds This is done to prevent the SSCx switching...

Страница 19: ...ocess data This concept for triggering the device status to Maintenance request can be applied to each avail able measured variable An Overrun Counter and Overrun Timer are therefore available for eac...

Страница 20: ...that the sensor thread is tightened with a tightening torque of 8 Nm Vibration sensor mounted in the wrong position The vibration behavior can vary depending on the measuring point mounting point Ther...

Страница 21: ...22 11 20 VIM3 IO Vibration Sensors Repair and Servicing 9 Repair and Servicing The device must not be repaired changed or manipulated In case of failure always replace the device with an original devi...

Страница 22: ...Pepperl Fuchs Quality Download our latest policy here www pepperl fuchs com quality www pepperl fuchs com Pepperl Fuchs Subject to modifications DOCT 8389...

Отзывы: