Product Description
Online Parameterization
When commissioning machines and plants, master and IO-Link devices must be integrated
into the appropriate control environment. Depending on the components used, different soft-
ware is required.
The devices can be configured and parameterized using an IO-Link configuration tool. During
operation, the parameters for the IO-Link devices can be checked and status and diagnostic
data can be read and monitored. IO-Link data is integrated into an application program using
function blocks.
2.2
Vibration Monitoring
2.2.1
Vibration Velocity Operating Range
The operating range of the vibration velocity is not constant over the entire measuring range. It
always depends on the current frequency at which the vibration sensor is vibrating.
Essentially, the higher the current frequency, the lower the detectable vibration velocity. This
can lead to a significantly high frequency, which can then lead to the current operating range of
the sensor in this state being smaller than the specified measuring range.
The maximum detectable operating range can be derived from the maximum detectable accel-
eration. This is 14 g (137.3 m/s
2
) for the entire frequency range.
The maximum measurable vibration velocity results from the following physical correlation:
The following applies to sinusoidal