4.
4.201
4
14
AS-i Safety Output Module with Diagnostic Slave
Product Description
5.5.1
LEDs
LEDs
Status
Signal // Description
PWR
green
No supply power
1 Hz
Supply power is on, safety-relevant address and/or AS-i AB address is “0” or no 24 V
ext. in (auxiliary power)
Supply power on
FAULT
red
AS-i communication OK
no data exchange with at least one AB slave
no 24 V ext. in (auxiliary power)
O 1, O 2
yellow
semiconductor output switched off
1 Hz
Error lock state, waiting for start signal, after transmission of start signal semiconductor
output switches on
8 Hz
The device is in an un-lockable error state. The devices resumes regular operation
after the Monitor sent the signal “error unlock”.
semiconductor output switched on
I1,
I2,
I3,
1.Y1
yellow
Corresponding input not switched on
running light
Switch is set to ON/PRG
Corresponding input switched
FAULT,
O1/O2
alternating
Periphery fault
LED on
LED flashing
LED off