HOST MODE PROGRAMMING
69
PARAMETER COMPLETE
PATH
SHC
PT
VALUE
3 = No Read
5 = Phase On
6 = Phase Off
8 = Multiple Read
9 = Right
10 = Wrong
11 = Ready
12 = Quality Counter <
Threshold
Alternative
Activation Event
/IO
/Out/Out1
/Active1
517
1
0 = None
1 = Complete Read
2 = Partial Read
3 = No Read
5 = Phase On
6 = Phase Off
8 = Multiple Read
9 = Right
10 = Wrong
11 = Ready
12 = Quality Counter <
Threshold
Deactivation Event
/IO
/Out/Out1
/Deactive
25
1
0 = None
7 = Timeout
5 = Phase On
6 = Phase Off
8 = Quality Counter >=
Threshold
Alternative
Deactivation Event
/IO
/Out/Out1
/Deactive1
518
1
0 = None
5 = Phase On
6 = Phase Off
8 = Quality Counter >=
Threshold
Deactivation
Timeout (ms)
/IO
/Out/Out1
/Timeout
26
0
Range: 40 to 15000
Activate On Any
Diagnostics Error
/IO
/Out/Out1
/ActiveDiagnoErr
555
1
0 = Disable
1 = Enable
Deactivate When
All Diagnostic Errors
Recovered
/IO
/Out/Out1
/DeactiveDiagnoNoErr
556
1
0 = Disable
1 = Enable