HOST MODE PROGRAMMING
67
4.7 DIGITAL I/O SETTING
PARAMETER COMPLETE
PATH
SHC
PT
VALUE
BUILT-IN DIGITAL INPUT LINES
Input 1 Active Level
Overridden by
Operating Mode
/IO
/In/In1Lev
229
1
0 = Active Closed
1 = Active Open
Input 2 active level
Overridden By
Operating Mode
/IO
/In/In2Lev
230
1
0 = Active Closed
1 = Active Open
Debounce Filter
(ms)
/IO
/In/InputTimeFilter
5035
0
Range: 5 to 1000
BUILT-IN DIGITAL OUTPUT LINES / OUTPUT 1
Use /IO
/Out/Out0
/Use_0
5316
1
1 = Local
2 = External Fieldbus
Line State
/IO
/Out/Out0
/Idle
19
1
0 = Normally Open
1 = Normally Closed
Activation Event
/IO
/Out/Out0
/Active
20
1
0 = None
1 = Complete Read
2 = Partial Read
3 = No Read
5 = Phase On
6 = Phase Off
8 = Multiple Read
9 = Right
10 = Wrong
11 = Ready
12 = Quality Counter <
Threshold
Alternative
Activation Event
/IO
/Out/Out0
/Active1
515
1
0 = None
1 = Complete Read
2 = Partial Read
3 = No Read
5 = Phase On
6 = Phase Off
8 = Multiple Read
9 = Right
10 = Wrong
11 = Ready
12 = Quality Counter <
Threshold