HOST MODE PROGRAMMING
32
PARAMETER COMPLETE
PATH
SHC
PT
VALUE
53 = 549
54 = 559
55 = 569
56 = 579
57 = 589
58 = 599
59 = 609
60 = 619
Min Code Position
Filter
/Codes
/Code#N
/MinCodePos
262
#N
0
Range: 0 to 255
Max Code Position
Filter
/Codes
/Code#N
/MaxCodePos
263
#N
0
Range: 0 to 255
Check Digit
/Codes
/Code#N
/CheckDigit
5
#N
1
0 = Disable
1 = Enable
Check Digit Type
(only for Interleaved
2 of 5)
/Codes
/Code#N
/CheckDigit25IL
526
#N
1
0 = Standard
1 = German
2 = DHL
3 = Daimler-Chrysler
4 = Bosch
Check Digit Type
(only for Code 39)
/Codes
/Code#N/
/CheckDigit39
527
#N
1
0 = Standard
1 = Mod 7
Check Digit
Transmission
/Codes
/Code#N
/CheckDigitTx
524
#N
1
0 = Disable
1 = Enable
Match String Rule
/Codes
/Code#N
/MatchStrRule
530
#N
1
0 = Match
1 = Do Not Match
Pattern Match
String
/Codes
/Code#N
/PatMatch
531
#N
3
Length: 0 to 200
Match Direction
Rule
/Codes
/Code#N
/MatchDirectionRule
529
#N
1
0 = Disable
1 = Forward
2 = Reverse
Code Label Local
No Read String
/Codes
/Code#N
/LocNoRead
18
#N
3
Length: 0 to 48