HOST MODE PROGRAMMING
50
PARAMETER COMPLETE
PATH
SHC
PT
VALUE
Main Port Electrical
Interface
/Comms
/SerMain/Line
/MainHW
10
1
0 = RS232
1 = RS485 Full Duplex
MUX 32 protocol
address
/Comms
/SerMain/Line
/Addr
58
0
Range: 0 to 31
Handshake
(RS232)
/Comms
/SerMain/Line
/FlowCtrl
57
1
0 = None
1 = Hardware (RTS/CTS)
2 = Software (Xon/Xoff)
Handshake
(RS485)
/Comms
/SerMain/Line
/Flow485
60
1
0 = None
1 = Software (Xon/Xoff)
Baud Rate (Mux32
Slave)
/Comms
/SerMain/Line
/StdBaud
49
1
8 = 1200
1 = 2400
2 = 4800
3 = 9600
4 = 19200
5 = 38400
6 = 57600
7 = 115200
Baud Rate (NOT
Mux32 Slave)
/Comms
/SerMain/Line
/MuxBaud
59
1
1 = 2400
2 = 4800
3 = 9600
4 = 19200
5 = 38400
6 = 57600
Parity /Comms
/SerMain/Line
/Parity
50
1
0 = None
1 = Odd
2 = Even
Data Bits
/Comms
/SerMain/Line/Data
51
1
0 = 7
1 = 8
Stop Bits
/Comms
/SerMain/Line/Stop
52
1
0 = 1
1 = 2
Checksum
(Siemens 3964)
/Comms
/SerMain/Line
/S3964Chk
535
1
0 = Disable
1 = Enable
Priority
(Siemens 3964)
/Comms
/SerMain/Line
/S3964Prio
536
1
0 = Low
1 = High
Header n. 5
(Siemens 3964)
/Comms
/SerMain/Line
/SRKHead5
540 3 Length:
1
Содержание VB14N