HOST MODE PROGRAMMING
20
After entering the programming string, the reader responds with the message:
Y<space>1<CR><LF>
- 3 -
Set
Device Name
parameter in
USER INFORMATION SECTION
folder:
Path: /UserInfo/Name
Shortcut: 522
Type: 2
(String)
Length:
0 to 128
Value: 2KN_FAMILY
The 'Set Parameter' programming string is:
SP<space>/UserInfo/Name:2KN_FAMILY<CR><LF>
The 'Set Shortcut' programming string is:
SS<space>522:2KN_FAMILY<CR><LF>
After entering the programming string the reader responds with the message:
Y<space>2KN_FAMILY<CR><LF>
- 4 -
Set
Header String
parameter in
DATA FORMAT
folder:
Path: /Comms/OutForm/Standard/Header
Shortcut: 6
Type:
3 (Binary String)
Length
0 to 128
Default:
HEADER (HEX value: 48H 45H 41H 44H 45H 52H)
The 'Set Parameter' programming string is:
SP<space>/Comms/OutForm/Standard/Header:6<space>484541444552<CR><LF>
The 'Set Shortcut' programming string is:
SS<space>6:6<space>484541444552<CR><LF>
Содержание VB14N
Страница 1: ...VB14N HOST MODE PROGRAMMING FACTORY AUTOMATION MANUAL...
Страница 91: ...HOST MODE PROGRAMMING...