2
0
1
7
-1
1
14
Installation
3.3
Electrical Connection
The reader is connected to an 8-pin M12 x 1 connector plug at the side of the housing with the
label
"Main"
. This connection is used to provide the power supply and communicate with the
peripherals in one. The configurable inputs and outputs for the reader are also available on this
connection.
Color Assignment
Fuchs single-ended female cordsets are manufactured in accordance with EN60947-
5-2. When using a type V19-... single-ended female cordset with an open cable end on the
Main
connection, the colors are assigned as follows:
Caution!
When selecting the length of the mounting screws, ensure that the maximum insertion depth of
the screws in the threaded inserts on the reader is 8 mm.
Using longer screws may damage the reader.
Caution!
The maximum torque of the mounting screws must not exceed 9 Nm.
Tightening the screws to a higher torque may damage the reader.
Plug Assignment
Connection Pin
Strand Color
Color Abbreviation
1
White
WH
2
Brown
BN
3
Green
GN
4
Yellow
YE
5
Gray
GY
6
Pink
PK
7
Blue
BU
8
Red
RD
1
2
3
4
5
6
7
8
OUT 2 / IN 2
+ UB
n.c.
n.c.
OUT 1
IN 1
GND
OUT 3 / IN 3
M
a
in
1
4
6
7
8
5
3
2
Main