2
0
1
7
-1
1
12
Installation
Figure 3.1
Zero line for code tapes
If the reader leaves the zero line when traversing along the X-axis, the threshold may deviate. If
the deviation exceeds the defined threshold, a warning code is issued.
Y-Axis Deviation Thresholds
3.2
Mounting of the Reader
Mounting the Reader
Make sure that you are able to mount the reader in a stable position. Before mounting the
reader, make sure that the travel of the moving system part is arranged so that this part does
not move outside of the reader's depth of focus range during operation.
1. Mount the reader on the moving part of the system and secure the reader in place using four
screws through the mounting adapter on the reader.
2. Mount the reader
vertically
so that the lens of the reader with the ring light and camera
module is aligned toward the code tape.
Figure 3.2
Vertical alignment tolerance
3. Alternatively, mount the reader
horizontally
so that the lens of the reader with the ring light
and camera module is aligned toward the code tape.
Hysteresis Y-Axis
Code Tape
Threshold
Number of Tracks
Width
Exit
Entry
1
15 mm
±
29 mm
±
25 mm
Y
0
X
Read distance
Code tape
30°
30°