2
0
1
7
-1
1
24
Operation and Communication
Warning Data Set
Global Primary Data
The global primary data allows you to parameterize the read head using PROFINET. The global
primary data is always transferred to the read head in full.
Bit No.
Content
Description
Word 1
1
WRN01 A code with non-PCV content was found
2
WRN02 Reader too close to code tape
3
WRN03 Reader too far from code tape
4
WRN04 Y position too large. The sensor is just before OUT
5
WRN05 Y position too small. The sensor is just before OUT
6
WRN06 The reader is rotated or tilted in relation to the code tape
7
WRN07 Low level of code contrast
8
WRN08 Repair tape detected
9
WRN09 Temperature too high
10
WRN10 Reserved
11
WRN11 Reserved
12
WRN12 Reserved
13
WRN13 Reserved
14
WRN14 Reserved
15
WRN15 Reserved
16
WRN16 Reserved
Table 5.1
If no warnings are present, all bits in the warning data set are set to 0.
Designation
Function
Parameter data
Primary data
Orientation
Orientation of read head in relation to
code tape
Orientation
0
°
0/180
°
180
°
Code Tape Type
Configuration of code tape width
Code tape width
1 row
2 rows
3 rows
4 rows
5 rows
6 rows
7 rows
8 rows
X-Resolution
Multiplier for the length in the
direction of the X coordinate
Resolution
0.1 mm
1 mm
10 mm
Y-Resolution
Multiplier for the length in the
direction of the Y coordinate
Resolution
0.1 mm
1 mm
10 mm
Speed-
Resolution
Multiplier for the velocity output
Resolution
0.1 m/s
0.01 m/s
0.001 m/s
Horizontal Offset Offset in the direction of the X
coordinate
Length
0 mm
–
±
10,000,000 mm
Input Function
Function at input signal
Function of input
No Function