Pulscon LTC
Function group "basic setup" (00)
D
O
C
T
-0
0
9
4
A
0
6
/2
009
12
07
82
15
3.4
Function "process propert." (004)
Use this f
u
nction to adapt the device reaction to the filling speed in the tank. The setting
impacts on an intelligent filter.
Selection:
•
standard
•
fast change
•
slow change
•
test:no filter
3.5
Function "end of probe" (030)
Use this f
u
nction to select the polarity of the pro
b
e end signal. If the pro
b
e end is
u
ncovered or in an ins
u
lated attachment, there is a negative pro
b
e end signal.
The signal from the pro
b
e end is positive if the attachment is gro
u
nded.
Selection:
•
free
•
tie down isol.
•
tie down gnd.
E
+
–
Selection:
Standard
Fast change
Slow change
Test: no filter
Application:
For all normal applications,
bu
lk solids and fl
u
ids at
low to medi
u
m filling speed
and s
u
fficiently large
tanks.
Small tanks, primarily with
fl
u
ids, at high filling
speeds.
Applications with strong
s
u
rface movement, e. g.
ca
u
sed
b
y stirrer, primarily
large tanks with slow to
medi
u
m filling speed.
Shortest reaction time:
- For test p
u
rposes
- Meas
u
rement in small
tanks at high filling
speeds, if "rapid
change" setting is too
slow.
2-wire electronics:
Dead time: 4 s
Rise time: 18 s
Dead time: 2 s
Rise time: 5 s
Dead time: 6 s
Rise time: 40 s
Dead time: 1 s
Rise time: 0 s
4-wire electronics:
Dead time: 2 s
Rise time: 11 s
Dead time: 1 s
Rise time: 3 s
Dead time: 3 s
Rise time: 25 s
Dead time: 0.7 s
Rise time: 0 s
E
+
–